Banner SureCross DX80G9M6S0P0M4M4 Manual

Banner SureCross DX80G9M6S0P0M4M4 Manual

Advertisement

SureCross DX80 Gateway
Configurable Gateway with 0 to 20mA analog inputs and outputs
IP67 Base
2.4 GHz
IP20 Base
900 MHz
For additional information, up-
dated documentation, and ac-
cessories, refer to Banner En-
gineering's website,
www.ban-
nerengineering.com/surecross.
Models
DX80G9M6S0P0M4M4
DX80G2M6S0P0M4M4
DX80G9M6S0P0M4M4C
DX80G2M6S0P0M4M4C
Internal antenna models are also available, but are not UL Listed. For more information, contact your local Banner Engineering Corp.
representative.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death. This device does not include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.
The SureCross® DX80 Wireless Network
FlexPower Node
and Battery Supply Module
Gateway
Node
P/N 134302 Rev. G
The SureCross® wireless system is a radio frequency network with integrated I/O that can operate in
most environments and eliminate the need for wiring runs. Wireless networks are formed around a
Gateway, which acts as the wireless network master device, and one or more Nodes.
• Wireless industrial I/O device with four 0 to 20 mA analog inputs and four 0 to 20 mA analog out-
puts
• 10 to 30V dc power input
• DIP switches for user configuration
• Modbus serial interface
• Site Survey analyzes the network's signal strength and reliability and displays the results on the
Gateway's LCD
• Frequency Hopping Spread Spectrum (FHSS) technology and Time Division Multiple Access
(TDMA) control architecture ensure reliable data delivery within the unlicensed Industrial, Scientific,
and Medical (ISM) band
• Transceivers provide bidirectional communication between the Gateway and Node, including fully
acknowledged data transmission
• Lost RF links are detected and relevant outputs set to user-defined conditions
• The DX80...C models are certified for use in Class I, Division 2, Group A, B, C, D; Zone 2 (Catego-
ry 3G) Hazardous Locations when properly installed in accordance with the National Electrical
Code, the Canadian Electrical Code, or applicable local codes/regulations (see Specifications)
Frequency
Environmental Rating
900 MHz ISM Band
IP67, NEMA 6
2.4 GHz ISM Band
900 MHz ISM Band
IP20, NEMA 1
Class I, Division 2, Group A, B, C, D Hazard-
2.4 GHz ISM Band
ous Locations (see Specifications)
Node
I/O
Inputs: Four 0 to 20 mA analog
Outputs: Four 0 to 20 mA analog
The SureCross® DX80 wireless I/O network provides reliable moni-
toring without wiring or conduit installation. The SureCross wireless
network operates independently or in conjunction with a host system,
PLC, and/or PC software.
Each wireless network system consists of one Gateway and one or
more Nodes. Devices ship with factory-defined discrete, analog, or a
mix of discrete and analog inputs and outputs.
The SureCross® DX80 network is a deterministic system—the net-
work identifies when the radio signal is lost and drives relevant out-
5/24/2013
0 134302
3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SureCross DX80G9M6S0P0M4M4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Banner SureCross DX80G9M6S0P0M4M4

  • Page 1 DX80G2M6S0P0M4M4C 2.4 GHz ISM Band ous Locations (see Specifications) Internal antenna models are also available, but are not UL Listed. For more information, contact your local Banner Engineering Corp. representative. WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death.
  • Page 2: Setting Up Your Wireless Network

    The UCT requires a special USB to RS-485 (model number BWA-UCT-900 for 1 Watt radios, BWA-HW-006 can be used for all other radios) converter cable to pass infor- mation between your computer and the Gateway. Download the most recent revi- sions of the UCT software from Banner Engineering's website: http://www.banneren- gineering.com/wireless.
  • Page 3: Dip Switch Settings

    SureCross DX80 Gateway 1. Unscrew the four screws that mount the cover to the bottom housing. 2. Remove the cover from the housing without damaging the ribbon cable or the pins the cable plugs into. 3. Gently unplug the ribbon cable from the board mounted into the bottom housing. 4.
  • Page 4: Terminal Blocks

    SureCross DX80 Gateway Following a radio link time-out, all outputs linked to the Node in question are set to de-energize (discrete outputs to zero, analog outputs to 0 mA or 4 mA), energize (discrete outputs to one, analog outputs to 20 mA), or to hold the last stable state/value. Use the DIP switches to select the link loss output state.
  • Page 5: Led Behavior For The Gateways

    SureCross DX80 Gateway Wiring Diagrams for Analog Inputs Connecting dc power to the communication pins will cause permanent damage. Do not exceed analog input ratings for analog inputs. Only connect sensor outputs to analog inputs. Analog Input Wiring (10 to 30V dc Pow- Analog Input Wiring (4–20mA, 2-Wire, Analog Input Wiring (4–20mA, 2-Wire, Externally Powered Sensors)
  • Page 6: Modbus Register Table

    SureCross DX80 Gateway Modbus Register Table Modbus Holding Register I/O Type Units I/O Range Holding Register Rep- Terminal resentation Block Labels Gateway / Any Node Min. Max. Min. (Dec.) Max. DX85 (Dec.) 1 + (Node# × 16) Analog IN 1 mA / V 20.0 / 10.0 65535...
  • Page 7 SureCross DX80 Gateway Radio and General Radio range is with the 2 dB antenna that ships with the product. For European applications, power the DX80 from a Limited Power High-gain antennas are available, but the range depends on the Source as defined in EN 60950-1. environment and line of sight.
  • Page 8: Banner Engineering Corp Limited Warranty

    ER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp.

This manual is also suitable for:

Surecross dx80 seriesSurecross dx80g2m6s0p0m4m4Surecross dx80g9m6s0p0m4m4cSurecross dx80g2m6s0p0m4m4c

Table of Contents