Banner SureCross DX80 Quick Start Manual

Banner SureCross DX80 Quick Start Manual

Ultrasonic node
Hide thumbs Also See for SureCross DX80:

Advertisement

Quick Links

SureCross DX80 Ultrasonic Node
Node with a battery and ultrasonic sensor integrated into the housing
For additional information, updated documentation, and accessories, refer to Banner Engineering's website,
ing.com/surecross.
Models
Frequency
DX80N9X1W0P0U
900 MHz ISM Band
DX80N2X1W0P0U
2.4 GHz ISM Band
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death. This device does not include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.
Binding Radios to Form Networks (Embedded Ultrasonic or Light Models)
The process of binding creates a secure wireless network between a Gateway and one or more Nodes. For the battery-powered Ultra-
sonic and Light Nodes, the Gateway should be set to 250 mW mode. Follow the instructions below to set the power level on the Gateway
and bind the wireless network.
On the Gateway
Step 1. Set the Extended Address Mode DIP switch (DIP switch 1) for DX80 Gateways or 250 mW mode DIP switch (DIP switch 1) for
DX80 Performance Gateways to the ON position.
1. Disconnect the Gateway from its power source.
2. Remove the Gateway's top cover.
3. Move DIP switch 1 to the ON position. (Refer to the datasheet for instructions on accessing the DIP switches.)
4. Apply power to the Gateway.
Step 2. Triple click button 2 to enter binding mode.
The red LEDs flash alternately when the Gateway is in binding mode. Any Node entering binding mode will bind to this Gateway.
Step 3. Assign the Node a Node Address. Using the Gateway's rotary dials, select the Node address to assign to the Node. Use the
left rotary dial for the left digit and the right rotary dial for the right digit. For example, to assign your Node to address 10, set the left dial
to 1 and the right dial to 0. (Address 00 is reserved for the Gateway. Nodes assigned to 00 will not bind to a Gateway.)
On the Node
Step 1. Place the optical commissioning device pointed directly at the LED receiving window.
Step 2. Triple-click the button on the optical commissioning device to place the Node into binding mode. (If the Node is in its "slow scan"
mode, this will wake up the Node as well as begin binding mode.)
P/N 164800 Rev. A
The SureCross® wireless system is a radio frequency network with integrated I/O that can oper-
ate in most environments and eliminate the need for wiring runs. Wireless networks are formed
around a Gateway, which acts as the wireless network master device, and one or more Nodes.
• Wireless industrial I/O device with an Ultrasonic sensor integrated into the housing
• FlexPower® technology driven by one lithium primary battery integrated into the housing
• Power-efficient occupancy sensor for parking applications
• Frequency Hopping Spread Spectrum (FHSS) technology and Time Division Multiple Access
(TDMA) control architecture ensure reliable data delivery within the unlicensed Industrial, Sci-
entific, and Medical (ISM) band
• Transceivers provide bidirectional communication between the Gateway and Node, including
fully acknowledged data transmission
Environmental Rating
IP67, NEMA 6
6/28/2013
www.bannerengineer-
I/O
Inputs: One Ultrasonic, one temperature
0 164800
1

Advertisement

loading

Summary of Contents for Banner SureCross DX80

  • Page 1 (TDMA) control architecture ensure reliable data delivery within the unlicensed Industrial, Sci- entific, and Medical (ISM) band • Transceivers provide bidirectional communication between the Gateway and Node, including fully acknowledged data transmission For additional information, updated documentation, and accessories, refer to Banner Engineering's website, www.bannerengineer- ing.com/surecross. Models...
  • Page 2 SureCross DX80 Ultrasonic Node After entering binding mode, the Node's LED blinks slowly, alternating between red and green. After the Node receives a valid binding code from the Gateway, the red and green LEDs are both illuminated continuously, resulting in a slightly orange light.
  • Page 3 As with all batteries, these are a fire, explosion, and severe burn hazard. Do not burn or expose them to high temperatures. Do not recharge, crush, disassemble, or expose the contents to water. Replacement battery model number: BWA-BATT-001. For pricing and availability, contact Banner Engineering. SureCross User Configuration Tool...
  • Page 4 ER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp.

This manual is also suitable for:

Dx80n9x1w0p0uDx80n2x1w0p0u