Banner SureCross DX80 Series Quick Start Manual

Banner SureCross DX80 Series Quick Start Manual

Node with discrete i/o
Hide thumbs Also See for SureCross DX80 Series:

Advertisement

Quick Links

SureCross DX80 Node with Discrete I/O
Configurable Node with eight discrete inputs and four discrete outputs
IP20 Base
900 MHz
For additional information, updated documentation, and accessories, refer to Banner Engineering's website,
ing.com/surecross.
Models
Frequency
DX80N9X6S8P4
900 MHz ISM Band
DX80N2X6S8P4
2.4 GHz ISM Band
DX80N9X6S8P4C
900 MHz ISM Band
DX80N2X6S8P4C
2.4 GHz ISM Band
Internal antenna models are also available, but are not UL Listed. For more information, contact your local Banner Engineering Corp.
representative.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death. This device does not include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.
SureCross User Configuration Tool
P/N 132160 rev. H
The SureCross® wireless system is a radio frequency network with integrated I/O that
can operate in most environments and eliminate the need for wiring runs. Wireless net-
works are formed around a Gateway, which acts as the wireless network master device,
and one or more Nodes.
• Wireless industrial I/O device with eight selectable discrete inputs and four sourcing
discrete outputs
• 10 to 30V dc power input
• DIP switches for user configuration
• Frequency Hopping Spread Spectrum (FHSS) technology and Time Division Multiple
IP67 Base
2.4 GHz
Access (TDMA) control architecture ensure reliable data delivery within the unlicensed
Industrial, Scientific, and Medical (ISM) band
• Transceivers provide bidirectional communication between the Gateway and Node, in-
cluding fully acknowledged data transmission
• Lost RF links are detected and relevant outputs set to user-defined conditions
• The DX80...C models are certified for use in Class I, Division 2, Group A, B, C, D;
Zone 2 (Category 3G) Hazardous Locations when properly installed in accordance
with the National Electrical Code, the Canadian Electrical Code, or applicable local co-
des/regulations (see Specifications)
Environmental Rating
IP67, NEMA 6
IP20, NEMA 1
Class I, Division 2, Group A, B, C,
D Hazardous Locations (see Speci-
fications)
The User Configuration Tool (UCT) offers an easy way to link I/O points in your wire-
less network, view I/O register values graphically, and set system communication pa-
rameters when a host system is not part of the wireless network.
The UCT requires a special USB to RS-485 (model number BWA-UCT-900 for 1 Watt
radios, BWA-HW-006 can be used for all other radios) converter cable to pass infor-
mation between your computer and the Gateway. Download the most recent revi-
sions of the UCT software from Banner Engineering's website:
gineering.com/wireless.
5/21/2013
www.bannerengineer-
I/O
Inputs: Eight selectable discrete
Outputs: Four sourcing discrete
(When your wireless network does not include a
host system, the eight input/four output Node must
be mapped to the four input/eight output Gateway.)
http://www.banneren-
0 132160
5

Advertisement

Table of Contents
loading

Summary of Contents for Banner SureCross DX80 Series

  • Page 1 DX80N2X6S8P4C 2.4 GHz ISM Band fications) Internal antenna models are also available, but are not UL Listed. For more information, contact your local Banner Engineering Corp. representative. WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death.
  • Page 2: Setting Up Your Wireless Network

    For additional information, including installation and setup, weatherproofing, device menu maps, troubleshooting, and a list of accesso- ries, refer to one of the following product manuals. • SureCross Quick Start Guide: Banner part number 128185 • SureCross Wireless I/O Network Manual: 132607 •...
  • Page 3 SureCross DX80 Node with Discrete I/O Switches Device Settings Inputs sourcing (PNP) OFF* Inputs sinking (NPN) Link loss output: zero OFF* OFF* Link loss output: one Link loss output: hold last state Link loss output: user configuration * Default configuration Address Mode The SureCross wireless devices may use one of two types of addressing modes: rotary dial addressing or extended addressing.
  • Page 4 SureCross DX80 Node with Discrete I/O DX80...C Wiring Wiring power to the DX80...C models varies depending the power requirements of the model. Connecting dc power to the communication pins (Tx/Rx) will cause permanent damage. For FlexPower devices, do not apply more than 5.5V to the gray wire. Terminal Label Gateway, DX85 10 to 30V dc Powered Nodes Battery Powered Nodes...
  • Page 5: Modbus Register Table

    SureCross DX80 Node with Discrete I/O Discrete Output Wiring (PNP) 10-30V dc Load dc common LED Behavior for the Nodes After powering up and binding the Gateway and its Nodes, verify all devices are communicating properly. A Node will not sample its inputs until it is communicating with its Gateway.
  • Page 6: Specifications

    SureCross DX80 Node with Discrete I/O Specifications Radio and General Range Power 900 MHz: Up to 4.8 kilometers (3 miles) Requirements: +10 to 30V dc (Outside the USA: +12 to 24V dc, ±10%). (See UL section below for any applica- 2.4 GHz: Up to 3.2 kilometers (2 miles) ble UL specifications) Transmit Power...
  • Page 7: Banner Engineering Corp Limited Warranty

    Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period.
  • Page 8 ER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp.

This manual is also suitable for:

Surecross dx80n9x6s8p4Surecross dx80n2x6s8p4Surecross dx80n9x6s8p4cSurecross dx80n2x6s8p4c

Table of Contents