Banner SureCross DX80 Series Manual

Node
Hide thumbs Also See for SureCross DX80 Series:

Advertisement

SureCross DX80 Node
Configurable Node with discrete inputs and discrete NPN outputs
IP67 Base
2.4 GHz
IP20 Base
900 MHz
For additional information, updated documentation, and accessories, refer to Banner Engineering's website,
ing.com/surecross.
Models
Frequency
DX80N9X6S6N6
900 MHz ISM Band
DX80N2X6S6N6
2.4 GHz ISM Band
DX80N9X6S6N6C
900 MHz ISM Band
DX80N2X6S6N6C
2.4 GHz ISM Band
Internal antenna models are also available, but are not UL Listed. For more information, contact your local Banner Engineering Corp.
representative.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death. This device does not include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.
SureCross User Configuration Tool
P/N 136324 Rev. F
The SureCross® wireless system is a radio frequency network with integrated I/O that can
operate in most environments and eliminate the need for wiring runs. Wireless networks are
formed around a Gateway, which acts as the wireless network master device, and one or
more Nodes.
• Wireless industrial I/O device with six selectable discrete inputs and six sinking discrete
outputs
• 10 to 30V dc power input
• DIP switches for user configuration
• Frequency Hopping Spread Spectrum (FHSS) technology and Time Division Multiple Ac-
cess (TDMA) control architecture ensure reliable data delivery within the unlicensed In-
dustrial, Scientific, and Medical (ISM) band
• Transceivers provide bidirectional communication between the Gateway and Node, in-
cluding fully acknowledged data transmission
• Lost RF links are detected and relevant outputs set to user-defined conditions
• The DX80...C models are certified for use in Class I, Division 2, Group A, B, C, D; Zone 2
(Category 3G) Hazardous Locations when properly installed in accordance with the Na-
tional Electrical Code, the Canadian Electrical Code, or applicable local codes/regulations
(see Specifications)
Environmental Rating
IP67, NEMA 6
IP20, NEMA 1
Class I, Division 2, Group A, B, C, D
Hazardous Locations (see Specifica-
tions)
The User Configuration Tool (UCT) offers an easy way to link I/O points in your wire-
less network, view I/O register values graphically, and set system communication pa-
rameters when a host system is not part of the wireless network.
The UCT requires a special USB to RS-485 (model number BWA-UCT-900 for 1 Watt
radios, BWA-HW-006 can be used for all other radios) converter cable to pass infor-
mation between your computer and the Gateway. Download the most recent revi-
sions of the UCT software from Banner Engineering's website:
gineering.com/wireless.
5/22/2013
www.bannerengineer-
I/O
Inputs: Six selectable discrete
Outputs: Six sinking discrete
http://www.banneren-
0 136324
9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SureCross DX80 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Banner SureCross DX80 Series

  • Page 1 DX80N2X6S6N6C 2.4 GHz ISM Band tions) Internal antenna models are also available, but are not UL Listed. For more information, contact your local Banner Engineering Corp. representative. WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death.
  • Page 2: Setting Up Your Wireless Network

    For additional information, including installation and setup, weatherproofing, device menu maps, troubleshooting, and a list of accesso- ries, refer to one of the following product manuals. • SureCross Quick Start Guide: Banner part number 128185 • SureCross Wireless I/O Network Manual: 132607 •...
  • Page 3 SureCross DX80 Node Switches Device Settings Inputs sourcing (PNP) OFF* Inputs sinking (NPN) Link loss output: zero OFF* OFF* Link loss output: one Link loss output: hold last state Link loss output: user configuration * Default configuration Address Mode The SureCross wireless devices may use one of two types of addressing modes: rotary dial addressing or extended addressing. In rotary dial address mode, the left rotary dial establishes the network ID and the right rotary dial sets the device ID.
  • Page 4: Terminal Blocks

    SureCross DX80 Node DX80...C Wiring Wiring power to the DX80...C models varies depending the power requirements of the model. Connecting dc power to the communication pins (Tx/Rx) will cause permanent damage. For FlexPower devices, do not apply more than 5.5V to the gray wire. Terminal Label Gateway, DX85 10 to 30V dc Powered Nodes Battery Powered Nodes...
  • Page 5: Modbus Register Table

    SureCross DX80 Node LED Behavior for the Nodes After powering up and binding the Gateway and its Nodes, verify all devices are communicating properly. A Node will not sample its inputs until it is communicating with its Gateway. When testing communication between the Gateway and Node, all radios and antennas should be at least two meters apart or the communications may fail.
  • Page 6 SureCross DX80 Node Radio and General 900 MHz Compliance (150 mW Radios) Housing FCC ID TGUDX80 - This device complies with FCC Polycarbonate housing and rotary dial cover; polyester Part 15, Subpart C, 15.247 labels; EDPM rubber cover gasket; nitrile rubber, non- sulphur cured button covers IC: 7044A-DX8009 Weight: 0.26 kg (0.57 lbs)
  • Page 7: Banner Engineering Corp Limited Warranty

    ER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp.

This manual is also suitable for:

Surecross dx80n9x6s6n6Surecross dx80n2x6s6n6Surecross dx80n2x6s6n6cSurecross dx80n9x6s6n6cSurecross dx80