30 November, 1999
Parameter
L2
Not adjustable
L3
This parameter changes the number of
scanner motor steps after the scan line
sensor is activated.
To increase the margin by x mm:
New setting = Current setting + 7.7x
To decrease the margin by x mm:
New setting = Current setting - 7.7x
6.11.3 PRINTER PARAMETERS
1. Margins (Main Scan Direction)
Parameter
W1
To increase the margin by x mm:
New setting = Current setting
+ x/0.5 (or 0.34)
To decrease the margin by x mm:
New setting = Current setting
- x/0.5 (or 0.34)
When the user sets the margin in the
main scan direction with a User
Function, the margin is added to this
setting.
W2
Not adjustable
Formula
Formula
H545R648.WMF
6-27
IMAGE ADJUSTMENT
RAM
Unit
Address
8002B8(H)
1
mm
7
7 .
(low)
8002B9(H)
(high)
RAM
Unit
Address
Standard
0.5
cassette:
mm
80036B(H)
(Fax)
Optional
0.34
paper feed
mm
unit:
(print
80036C(H)
er)
Optional
multi-
purpose
feeder:
800370(H)
Initial
Setting
9B(H)
[155(D)]
Initial
Setting
08(H)
08(H)
07(H)