Ncu Parameters - Ricoh FAX2000L Service Manual

Hide thumbs Also See for FAX2000L:
Table of Contents

Advertisement

30 November, 1999

4.3 NCU PARAMETERS

The following tables give the RAM addresses and the parameter calculation units
that the machine uses for ringing signal detection and automatic dialing. The
factory settings for each country are also given. The RAM read/write (Function 06)
must change most of these, but NCU Parameter programming (Function 08) can
change some others; if Function 08 is in use, the Remarks column indicates it. The
RAM is in hex code unless (BCD) is included in the Unit column.
Address
807F00
Country code for NCU parameters
807F01
Line current detection time
807F02
Line current wait time
807F03
Line current drop detect time
Function
4-37
NCU PARAMETERS
Unit
Remarks
Use the Hex value to program the
country code directly into this address,
or use the decimal value to program it
using Function 08 (parameter C.C.).
Country
Decimal
France
00
Germany
01
UK
02
Italy
03
Austria
04
Belgium
05
Denmark
06
Finland
07
Ireland
08
Norway
09
Sweden
10
Switzerland
11
Portugal
12
Holland
13
Spain
14
Israel
15
USA
17
Asia
18
Hong Kong
20
South Africa
21
Australia
22
New Zealand
23
Singapore
24
Malaysia
25
China
26
Taiwan
27
Greek
33
20 ms
Line current is not detected
if 807F01 contains FF.
Hex
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
11
12
14
15
16
17
18
19
1A
1B
21

Advertisement