12 STANDARDS
12.1 ELECTRICAL CONSUMPTIONS
Average consumptions device waiting for host solicitation :
o iUP250 – PINPad < 100 mA
Value measured for Power supply 12V at 25°C
o iUR250 – Reader < 50 mA
Value measured for Power supply 12V at 25°C
Indicative consumption device when contact card transaction is performed :
Hypothesis: no radio (GPRS) reader iUR250 only connected to iUP250
o iUP250 + iUR250 < TBC
Value measured for Power supply 12V at 25°C
Maximum average external supply current:
o iUP250 – PINPad < 2 A
Value measured for Power supply 12V at 25°C
iUR250 – Reader < 0,5 A
Value measured for Power supply 12V at 25°C
Maximum consumption in stand-by mode (12 VDC input.):
o iUP250 – PINPad < 400µA
Value measured for Power supply 12V at 25°C
o iUR250 – Reader < 50µA
Value measured for Power supply 12V at 25°C
12.2 TEMPERATURE AND HUMIDITY
Operating & Storage conditions :
o Relative humidity: 5% to 85% non-condensing.
o External temperature range: -20 °C to 65 °C.
Intégration Guide_iUP250&iUR250
900009151 R11 000 01/1223
79/83
Copyright © 2012 Ingenico
All rights reserved