10 STANDARDS

10.1 IUC 150 ELECTRICAL CONSUMPTIONS

• Average consumptions device waiting for host solicitation (5 VDC input.):
- Less than 50 mA
Value measured for Power supply 5V at 25° C
• Maximum average external supply current (5 VDC input.):
- Less than 500 mA
Value measured for Power supply 5V at 25° C
• Maximum consumption in stand-by mode (5 VDC input.):
- Less than 50µA
Value measured for Power supply 5V at 25° C

10.2 IUC 180 ELECTRICAL CONSUMPTIONS

• Average consumptions device waiting for host solicitation (12 VDC input.):
- Less than 120 mA
Value measured for Power supply 5V at 25° C
• Maximum average external supply current (12 VDC input.):
- Less than 2500 mA
Value measured for Power supply 5V at 25° C
• Maximum consumption in stand-by mode (12 VDC input.):
- Less than 400 µA
Value measured for Power supply 5V at 25° C

10.3 TEMPERATURE AND HUMIDITY

• Operating & Storage conditions :
o Relative humidity: 5% to 85% non-condensing.
o External temperature range: -20 ° C to 65 ° C.

10.4 ENVIRONMENTAL SPECIFICATION CONTINUED

• Operating conditions :
o Front face shock resistance: IK10
o Vibrations resistance: 5-9Hz, 6.2mm; 9-200Hz, 1g; 200-500 Hz, 1.5g;
10ct/mn, 10 Cycles
o Bumps resistant: 6ms, 25g, 500 cycles each direction
• Natural events:
o Water and dust resistant IP64 for iUC180 and iUC150 (outside the
kiosk).