12.3 ENVIRONMENTAL SPECIFICATION CONTINUED

 Operating conditions :
o Front face shock resistance: IK10
o Vibrations resistance: 5-9Hz, 6.2mm; 9-200Hz, 1g; 200-500 Hz, 1.5g;
10ct/mn, 10 Cycles
o Bumps resistant: 6ms, 25g, 500 cycles each direction
 Natural events:
o Water and dust resistant IP65 for iUP250 and IP34 for iUR250
 Degradation iUP250 –iUR250 specification:
o Vandal resistant.
o Impact resistant IK10.
o Certified anti-tamper and attack resistant.
 Drop iUP250 –iUR250 specification:
o Drop 1m on concrete surface all faces

12.4 EC STANDARD COMPLIANCE MARKING

EC standard compliance marking certifies that the product stipulated below:
iUR250
iUP250
Conforms to the following harmonized standards:
 IEC/EN 60950-1: Electrical safety of data processing equipment including
electrical office equipment. Issue dec. 2001
 EN 55022: Data processing equipment – Radiofrequency disturbance
characteristics - Limits and measurement methods. EN 55022 2006 + A1
(2007)
 EN 55024: Data processing equipment – Immunity characteristics - Limits and
measurement methods. Issue 1998 + A1- 2001 + A2 – 2003
Intégration Guide_iUP250&iUR250
900009151 R11 000 01/1223
80/83
Copyright © 2012 Ingenico
All rights reserved