Software Downloading - Ingenico iUP 250 Integration Manual

Table of Contents

Advertisement

3.1.5 Software downloading

Downloading
The software can be downloaded:
 Locally via the serial link (COM or USB).
 Remotely, via the switched telephone network (PSTN) using an external
modem, Ethernet, GPRS, TCP/IP network.
 By a USB key. The iUP250 must be in maintenance mode with a USB key
containing the software to load plugged in. Then, launch the download by
using the manager menu.
The techniques used:
 Data compression,
 Authenticity checking,
 Memory allocation management,
 TCP/IP,
best optimize the software downloading operations.
These features provide faster downloading time, enhanced security, an ease in
upgrading, and a larger number of software installed on the system unit.
Local Loading Tool (LLT)
The LLT is used for local software download.
The LLT is formed by:
 A PC running with Windows Seven, Vista Pro, XP, 2003 Server, 2000
Professional SP2
 A INGENICO loading software,
 A PC-terminal connecting cable
Local loading is performed:
 From a PC equipped with the Local Loading Tool (LLT) on the COM serial or
slave USB link
 By automatic switching to the local loader of the operating system.
Two connections are possible:
 By COM link:
 By slave USB link:
Selection of the software to be loaded is guided on the PC screen by an Explorer
type Windows system (Windows loader).
Loading time for a 1Mo application is 4s by USB port.
Intégration Guide_iUP250&iUR250
900009151 R11 000 01/1223
Speed 115200 bits/s
Speed 8 Mbits/s approx.
43/83
Copyright © 2012 Ingenico
All rights reserved