40
ATS Control Panel
Manager's manual

10. Inhibit zone

Use this function to inhibit zones and exclude them from the security system. A zone is inhibited when it is
faulty or broken (that is, it is active). By inhibiting it, you prevent it causing an alarm until it is fixed. You can
also inhibit normal zones if you know their zone number.
An inhibited zone is by default inhibited only until the next disarm of the area to which it belongs.
To inhibit a zone
1. Access menu option 10.
What happens next depends on whether or not there are active zones.
No active zones
All Zones are Normal
Inhibit:
2. From the display you can now:
Option
Inhibit the selected zone
Update the list of active zones
Exit
1. If the active zones are shown as a list of numbers, it is not possible to display the name of the zone.
2. If an attempt is made to inhibit a zone that is already inhibited, the request appears as if it is processed but it is not
logged in the history and the zone remains inhibited.
3. As soon as a zone that is in alarm is inhibited, the alarm is reset.
See also:
Uninhibit zone, page 41.
Zones are active
Active zones are listed either one at a time, or as a list of
numbers:
Active On 4, PIR In Managers Office
Inhibit :
or
Active On 1, 2, 4.
Inhibit:
Action
Result
Enter the zone number
Inhibits the selected zone (this removes the zone from the
and press [ENTER]
display and replaces it with the next active zone in the list).
Press [NEXT]
Updates the list of active zones (if any).
Press [ENTER]
Exits the menu option.