  • Page 1: Control Panel

    ATS2000/3000/4000/4500 Control Panel Quick Programming Guide Version 2.0, August 2003...
  • Page 2 Aritech is a GE Interlogix brand. www.GE-Interlogix.com Copyright (c) 2003 GE Interlogix B.V.. All rights reserved. GE Interlogix B.V. grants the right to reprint this manual for internal use only. GE Interlogix B.V. reserves the right to change information without notice.
  • Page 3 ONTENTS Contents ................................3 Quick Programming Guide........................4 Defaulting the panel to factory defaults (using the ‘Kill’ jumper) ............4 Powering up the panel ........................4 Disarming the system........................4 Defaulting the panel to factory defaults (using Menu 14) ..............4 Entering the ATS menu........................4 Entering the programming menu to program the system ..............4 Changing parameters in the programming (examples) ..............5 Programming zones ........................5 Change manager code........................5...
  • Page 4: Quick Programming

    a r t h L u g 1 7 - P o w e r y s t e m e a r t h 2 V b a t t e r y . 1 4 - A u x i l i a r 1 3 S i r e n s / S x t e r n a l 8 O h K r e s i s t o r m...
  • Page 5: Programming Sequences

    0 (not used). press * to access the Advanced Menu) The - assigning areas 1-8 to zones. following display appears: ATS4000 only allows for: -256 zones not being programmed with zone type 0 (not used). Installer Programming - assigning areas 1-16 to zones.
  • Page 6 2. P ROGRAMMING Menu 19 Legend Simple menus Simple/Advanced Menu *-Advanced Advanced menus 1. Zone Database 1. Zone number 1. Zone name 2. Zone type 3. Reporting of zone 4. Report alarm to CS 1 5. Report alarm to CS 2 6.
  • Page 7 2. Area Database 1. Select the area to program 1. Area name 2. Exit time 3. Entry time 4. External Siren event flag 5. Internal Siren event flag 6. Area disarmed event flag 7. Area active event flag 8. Inhibited event flag 9.
  • Page 8 5. Alarm Groups 1. Number 1. Alarm group name 2. Areas assigned 3. User alarm group 4. Alarm system control 5. List areas 6. Keypad duress 7. Reset system alarm If "SKIP" 8. Disable auto-uninhibit 9. Arm & reset only 10.
  • Page 9 24. Sirens only after report fail 7. System options 1. Area/s selected to total disarm 25. Financial options 2. Film low level is set to 26. Display user flags 3. Film out level is set to 27. Delayed disarmed alarm lockout 4.
  • Page 10 10. Program text 1. Program text words 1. Select the device to 11. Version number get information on 12. Lamp test 13. Time zones 1. Select timezone 1. Program start time, hours. 2. Program start time, minutes 14. Defaults 1. Select default option 3.
  • Page 11 22. Timezone to follow output 1. Select timezone 1. Assign output to follow 23. Poll errors 1. Select device type 1. Display download status 24. Download to remote device 1. Select download option 2. Download all 25. Display last card 26.
  • Page 12 32. Custom LCD message 33. Program next service 1. Maintenance date 2. Maintenance message 1. Mains fail event flag 15. Not used Program system event flags 16. Not used 2. Low battery event flag 3. Fuse fail event flag 17. Dialler active event flag 4.
  • Page 13 44. Reserved Menu 45. Reserved Menu 46. Reserved Menu 47. Reserved Menu 48. Reserved Menu 49. Reserved Menu 50. Channel Mapping 1. Inputs Input Group 1 - 16 2. Areas Area Group 1 - 8 3. System System Group 1 - 10 Event Channel (Default) Channel Type...
  • Page 14 ATS2000/3000/4000/4500 Quick Programming Guide...
  • Page 15 ATS2000/3000/4000/4500 Quick Programming Guide...
  • Page 16 1045454...