12. Test zone

Use this function to test if an individual zone is operating correctly.
To test a zone
1. Access menu option 12.
The display shows:
2. Enter the zone number you want to test and press [ENTER], or
press [ENTER] to exit and return to the menu.
3. If you selected a zone, one of four responses is displayed:
The zone is normal.
The zone is active.
There is a faulty condition due to cable tamper. The cabling to the zone shows an OPEN
circuit.
There is a faulty condition due to cable tamper. The cabling to the zone shows a SHORT
circuit.
4. Press [ENTER] to exit and return to the menu option display.
1. If a zone is active, open or short, the keypad emits a continuous tone. When the status of the zone is changed to normal,
the display is updated and the tone stops.
2. If the zone is inhibited when a test is requested on it, the system uninhibits the zone, conducts the test, and then returns
the zone back to inhibited.
3. The test must be carried out within a pre-determined time. If the test is not completed within this time, the option is
closed.
Test Individual Zone:
Zone No:
Example
NORMAL STATE on 12, Roller Door
:
Press ENTER
Example
ACTIVE on 12, Roller Door
:
Press ENTER
Example
OPEN on 12, Roller Door
:
Press ENTER
Example
SHORT on 12, Roller Door
:
Press ENTER
:
:
: