Yamaha CL5 Reference Manual page 299

Digital
Hide thumbs Also See for CL5:
Table of Contents

Advertisement

4.8
FUNCTION CALL - CHANNEL -
4.8.1 Pair ON/OFF Trigger Format (PARAMETER CHANGE)
Reception
Data will be received when [PARAMETER CHANGE Rx] is on and the Device
number of both [Rx CH] and SUB STATUS match.
The data will be echoed when [PARAMETER CHANGE ECHO] is on.
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacturer's ID number (YAMAHA)
SUB STATUS
0001nnnn 1n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
Digital mixer
MODEL ID
00011001 19
CL Series
DATA CATEGORY 00000000 00
OTHER DATA
FUNCTION NAME 01000011 "C"
01101000 "h"
01101100 "l"
01010000 "P"
01101001 "i"
01110010 "r"
01000011 "C"
01110000 "p"
MODULE NAME
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
DATA
0sssssss sh
Source Channel Number H *1)
0sssssss sl
Source Channel Number L *1)
0ddddddd dh
Destination Channel Number H *1)
0ddddddd dl
Destination Channel Number L *1)
EOX
11110111 F7
End of exclusive
4.8.2 Module Name
Module Name
Pair On (with Copy)
"PAIRONCP"
Pair On (with Reset Both)
"PAIRONRS"
Pair Off
"PAIROFF_"
*1)
0:CH1
- 71:CH72
256:MIX 1 - 279:MIX 24
512:MATRIX 1-519:MATRIX 8
4.9 LEVEL METER DATA
4.9.1 Format (PARAMETER CHANGE)
When transmission is enabled by receiving Request for Level Meter, the
corresponding metering data will be sent in every 50 millisecond for 10 seconds.
If metering information is expected to be continuously sent, Request is needed to
be sent in at least every 10 seconds.
Reception
The data will be echoed when [PARAMETER CHANGE ECHO] is on.
Transmission
When transmission is enabled by receiving Request, the corresponding metering
data will be sent in constant interval for a given period of time (The interval and
time will vary depending on devices).
When rebooted or port setting is changed, the transmission will be disabled.
When [PARAMETER CHANGE ECHO] is on, the message will be sent as it is.
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacturer's ID number (YAMAHA)
SUB STATUS
0001nnnn 1n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
Digital mixer
MODEL ID
00011001 19
CL Series
DATA CATEGORY 00100001 21
REMOTE LEVEL METER
DATA
0mmmmmmm
mm
ADDRESS
UL
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
0ddddddd dd
Data1
:
:
EOX
11110111 F7
End of exclusive
4.9.2 Format (PARAMETER REQUEST)
Reception
Data will be received when [PARAMETER CHANGE Rx] is on and the Device
number of both [Rx CH] and SUB STATUS match.
The data will be echoed when [PARAMETER CHANGE ECHO] is on.
The corresponding metering data will be sent via [Rx CH] in constant interval for
a given period of time (The interval and time will vary depending on devices).
If this is received with an Address UL = 0x7F, transmission of all meter data will
stop (will be disabled) immediately.
Transmission
When [PARAMETER CHANGE ECHO] is on, the message will be sent as it is.
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacturer's ID number (YAMAHA)
SUB STATUS
0011nnnn 3n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
Digital mixer
MODEL ID
00011001 19
CL Series
DATA CATEGORY 00100001 21
REMOTE LEVEL METER
DATA
0mmmmmmm mm
ADDRESS UL
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
0ccccccc ch
Count H
0ccccccc cl
Count L
EOX
11110111 F7
End of exclusive
42
Data List

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl1Cl3

Table of Contents