__________________________ Note _____________________________
If you are unsure about the environment values, accept the default values of 0. If
these values are incorrect for your system, (for example, if your hard disk drives
are on a SCSI bus 1, through a secondary controller), Windows NT setup will
prompt you to run the ARCINST utility. The ARCINST utility provides valid
values that you can use to set this environment variable correctly. (Refer to
Appendix E for information on running the ARCINST utility.)
____________________________________________________________
5. Enter the partition number on the disk, which should be 2, and press [Enter].

Set Default Configuration

The Set default configuration command is located in the Setup menu. Use this
command to select:
Monitor resolution
Diskette drive capacity
Keyboard language
SCSI controller (host) ID (typically, 7)
EISA bus configuration
For example, when selected, the Set default configuration command prompts
you to make the following choices:
Select monitor resolution:
1280x1024
1024x768
800x600
640x480
Select first floppy drive capacity:
5.25" 1.2MB
3.5" 1.44MB
3.5" 2.88
none
Console Commands