1.3.4 Configuration Display
The configuration display shows the system configuration and the error messages
that were detected while the most recent power-up tests, diagnostic tests, and
utilities were running. If you add expansion boxes to the system and do not run
the power-up tests or appropriate diagnostic test or utility, the configuration
display does not recognize the reconfiguration. Enter the following command to
see the configuration display:
>>> SHOW CONFIG
If the system does not detect any errors in the most recent power-up tests
or diagnostic utilities, it responds with a configuration display similar to the
following:
KA55-A or KA51-A V2.3, VMB 2.14
08-00-2B-33-CF-C9
80MB
¡
¢
TstNbr DevNam
Info
------ --------
--------------------------
0
CPU_BD
OK
A8
MEM
OK
E4
DZ
OK
E0
SCSI
OK
3-RZ24L
5F
NI
OK
F0
SCSI_B
OK
0-RZ23L
0
QBUS
OK
E8
COMM
OK
DSW41/42 2 CHANNEL V4.10-7b
EC
ASYNC
OK
DHW41/2 V1.6
Test Utility Number Column
Device Mnemonic Column
¡
Device Status Column
¢
SCSI IDs and SCSI Device Names
£
The test numbers listed identify the normal test or script number to run to verify
the device listed. There are additional tests and utilities for some devices. Test 0
calls the power-up script.
1–22 Troubleshooting and Diagnosing Problems
6-Adapter 7-RRD43
£
6-Adapter