Total Harmonic Distortion
(THD-F with respect to the fundamental frequency, min. value at 50 or 60 Hz is
voltage > AC 80V and current is:
830+
6802> 20A;
th
50
Harmonics. If the voltage or current is 0 at 50 or 60 Hz, all the percentage (%)
display is 0).
PCE-830 + PCE-6801
Range
0.0 – 20.0 %
20.0 – 100%
100 – 999.9%
PCE-830 + PCE-6802
Range
0.0 – 20%
20 – 100%
100 – 999.9 %
PCE-830 + PCE-3007
Range
0.0 – 20%
20 – 100%
100 – 999.9 %
830 +
830+
3007> 30A. Calculation is done over 1 to
Resolution
0.1%
Resolution
0.1%
Resolution
0.1%
0.1%
0.1%
55
6801> 10% of the range;
Accuracy
± 1%
±3% of reading ± 5%
±10% of reading ±10%
Accuracy
± 2%
± 6% of reading ± 1%
± 10% of reading ± 1%
Accuracy
± 2%
± 6% of reading ± 5%
± 10% of reading ± 10%