PCE Instruments PCE-P05 Instruction Manual

PCE Instruments PCE-P05 Instruction Manual

Hvac meter pce-p series

Advertisement

Quick Links

Instruction Manual
HVAC Meter PCE-PXX

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PCE-P05 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PCE Instruments PCE-P05

  • Page 1 Instruction Manual HVAC Meter PCE-PXX...
  • Page 2: Table Of Contents

    INTRODUCTION ........................3 CONVERSION ........................3 CONROLS AND INDICATORS ....................3 AUTO POWER OFF (SLEEP FUNCTION) ................4 MODE OPTIONS ......................... 4 MAINTENANCE ........................5 CALIBRATION MODE ......................6 CALIBRATION POINT REFERENCE ................. 7 MANUAL ZERO SETTING ....................7 TROUBLESHOOTING ......................7 REPLACING THE BATTERY ....................
  • Page 3: Introduction

    11 pressure units are selectable for Imperial and Metric in the different area: bar, mmHg, ozin², kgcm², psi, inH2, kPa, ftH2O|, inHg, cmH2O, mbar. Please check the tubing is not leakage or damaged before using • CONVERSION Manometer Inch of mbar kg/cm³ PCE-P05 0,35 PCE-P15 1034 1,05 PCE-P30 2068 2,10 PCE-P50...
  • Page 4: Auto Power Off (Sleep Function)

    Note: There e are two co onnecting me etal lug 5mm m, plastic lug g 9.25mm fo or different a application pu urpose . Ma sure which o one you wan t before purc chasing the u unit. AUTO POW WER OFF (SL LEEP FUNC TION)
  • Page 5: Maintenance

    Pres ss momentar rily to freeze the pressure e reading. (F Fig. E) Pres ss momenta arily, DIF ap pears on to op of the LC CD and tile display indi cates the re elative zero (Rel ative zero ca auses the va alue of the dis splay to show...
  • Page 6: Calibration Mode

    CALIBRATI ON MODE Calibration m mode is only applicable fo or a standard d Manomete er calibrator o or any qualifi ed meter ca libration facil lity for annual ca alibration, 1. First t, please ma nually set the e display to z zero (no pres ssure applied d to the conn...
  • Page 7: Calibration Point Reference

    CALIBRATION POINT REFERENCE Model psi-range Calibration point (±) Recommend PCE-P05 0 ~ ±5 4,000 3,900 ~ 4,100 PCE-P15 0 ~ ±15 12,00 11,70 ~ 12,30 PCE-P30 0 ~ ±30 24,00 23,40 ~ 24,60 PCE-P50 0 ~ ±100 80,00 78,00 ~ 82,00...
  • Page 8: Specification

    SPECIFICATION PCE-P05 PCE-P15 PCE-P30 PCE-P50 Range 0 – 5 psi 0 – 15 psi 0 – 30 psi 0 – 100 psi Resolution 0,003 psi 0,01 psi 0,02 psi 0,1 psi Accuracy ±0,3% of full scale at 25°C Dimension 72 x 182 x 30 mm Unit Weight Approx.