HLI-PRC Addressing Scheme
HLI Addressing Overview
■
HLI Addressing of CAPs
■
HLI Addressing of Tape Drives
■
HLI Addressing Overview
HLI-PRC addressing designates physical location using: LSM, Panel, Row, and
Column.
LSM
Always equal to 0.
Panel
Indicates the front wall (CAP side) or rear wall (drive side) of a module. The panel
number can range from 0 to 23 depending on the configuration of the library.
Rear wall = even numbers
■
Front wall = odd numbers
■
The panel location is defined relative to the Base Module (panels 12 and 13). Panel
values less than 12 indicate the module is to the left of the Base Module, while values
greater than 13 indicate the module is to the right of the Base Module.
Base Module
Panels 12 and 13
■
DEM
Panels 10 and 11
■
CEM
Panels are numbered consecutively from the adjacent module. However, if there is
■
no DEM, a CEM placed directly to the left of a Base Module contains panels -8 and
-9 (panels -10 and -11 are skipped).
AEM
AEMs are considered CAPs by HLI addressing. Therefore, AEMs have a CAP ID
■
instead of a panel number (see
Left AEM CAP ID is always numbered 0
■
Right AEM CAP ID is always numbered 11
■
Row
The vertical location of a slot, consecutively numbered from the top down (0 to 51).
However, drive bays have row numbering from 0 to 23 for the Base Module, and 0 to
31 in the DEM.
Column
The horizontal location of a slot from left to right (0 to 5). However, drive bays always
have a column value of 0 (see
AEM column numbering starts at the rear wall and runs left to right (columns 0–2),
then proceeds to the front wall and runs left to right (columns 3–5).
"HLI Addressing of CAPs"
"Tape Drive Hardware Numbering"
HLI-PRC Addressing Scheme
on page E-8)
on page E-15").
Library Addressing Reference E-7