Ethernet Switch Agent Object - Hirschmann RS20 User Manual

Industrial ethernet (gigabit-)switch with software l2e, l2p, l3e or l3p
Hide thumbs Also See for RS20:
Table of Contents

Advertisement

EtherNet/IP

2.2.4 Ethernet Switch Agent Object

The Switch supports the Hirschmann-specific Ethernet Switch Agent Object
(class code f5hex = 149dec) for the Switch configuration and information pa-
rameters with an instance (instance 1).
You will find further information on these parameters and how to set them in
the "Web-based Interface" reference manual.
Switch Status ID 01
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 16
Bit 17
Bit 21
Bit 22
Bit 23
Bit 24
Bit 25
Bit 28
Bit 29
Bit 30
Switch
ID 02
Temperature
Reserved
ID 03
Table 7: Hirschmann Ethernet Switch Agent Object
22
DWORD (32 bit) RO
Overall state (0=ok, 1=failed). Like the signal contact.
Power Supply 1 (0 =ok, 1 =failed or does not exist)
Power Supply 2 (0 =ok, 1 =failed or does not exist)
Power Supply 3 (0 =ok or not possible on this platform,
1 =failed or does not exist)
Power Supply 4 (0 =ok or not possible on this platform,
1 =failed or does not exist)
Power Supply 5 (0 =ok or not possible on this platform,
1 =failed or does not exist)
Power Supply 6 (0 =ok or not possible on this platform,
1 =failed or does not exist)
Power Supply 7 (0 =ok or not possible on this platform,
1 =failed or does not exist)
Power Supply 8 (0 =ok or not possible on this platform,
1 =failed or does not exist)
DIP RM (ON=1, OFF=0)
DIP Standby (ON=1, OFF=0)
Signal Contact 1 (0=closed, 1=open)
Signal Contact 2 (0=closed, 1=open)
Temperature (0=ok, 1=failure)
Fan (0=ok or no fan, 1=failure)
DIP Ring Ports (Module 2 Port 1&2 = 1, Module 1 Port 1&2 = 0)
DIP Configuration (enabled = 1, disabled = 0)
DIP HIPER-Ring State (ON=1, OFF=0)
Module removed (1=removed)
ACA removed (1=removed)
Hiper-Ring (1=failure)
Ring-/Netcoupling (1=failure)
Connection Error (1=failure)
Struct{INT RO Temperature °FINT RO Temperature °C}
Always 0, attribute is reserved for future use.
2.2 EtherNet/IP Parameters
Industrial Protocols
Release 5.0 04/09

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents