4. When the set gas volume is reached:
-
The calculated gas flow rate and the gas burner capacity
(in kW) are displayed.
6.2.10.
| Oil flow rate
The function is only available if the chosen fuel is an oil.
This function is used to calculate the capacity of the burner from
the set oil pressure and the oil flow rate of the oil nozzle.
> Set the oil flow rate of the oil nozzle and the oil pressure
-
The calculated oil burner capacity (in kW) is displayed.
6.3.
Printing readings
The current readings can be printed using a report printer
(accessories: Testo printer 0554 0621).
Making print text settings
The reading printout can be supplemented with individual
information (header: company address; footer: name of technician).
1.
2. Make the settings.
A logo cannot be included in the reading printout. This is only used
for a report issued in PDF format.
Printing current readings
✓ The printer is switched on and within wireless range.
>
|
Protocols
|
Own Company
|
Print
values.
6 Using the product
.
Data.
25