6 Using the product
✓ The gas pressure set (0554 1203) must be connected.
✓ The minus connection for differential pressure measurement
must be depressurised at the beginning of measurement
(ambient pressure; the instrument not connected to the system
being checked), as the pressure sensor is zeroed.
1.
-
Zeroing the pressure sensor.
-
The reading is displayed.
2. Connect the instrument to the system being checked.
3.
6.2.7.
| Differential temp.
✓ The differential temperature set (0554 1208) must be
connected.
1.
-
The measured values and the calculated differential
temperature
2.
6.2.8.
| O
1.
-
The reading is displayed.
2.
6.2.9.
| Gas flow rate
The function is only available if the chosen fuel is a gas.
The gas burner capacity is calculated by means of the volume of
gas consumed. To this end, a volume of gas is input into the app
and its consumption read out at the gas meter.
1. Set the volume of gas to watch for at the gas meter.
2. Set the calorific value of the burnt gas.
3.
-
The measurement period is displayed.
24
.
Do not measure for longer than 5 minutes, as the drift of the
pressure sensor could mean that the measured values are
outside the tolerance limits. Re-zero the pressure sensor for
longer measurements.
.
.
∆t
(T1 - T2) are displayed.
.
supply air
2
.
.
.