Epson PX-8 Technical Manual page 36

Hide thumbs Also See for PX-8:
Table of Contents

Advertisement

~----
REV.-A
• When eight hours have elapsed after the ac adaptor is connected to the AC line, port 41 of the
4-bit sub-CPU goes high, cutting off transistor
09.
This puts the circuit in the trickle charging
state by inserting the resistors R3 and R5 (combined resistance, 41 ohms) in the charging path
in series. The circuit constants are selected in this state so that the battery is substantially not
harmed by overcharge, even if the battery is continually charged.
*Reference
Following is the sub-CPU port operation for power control:
Table 2-2 Sub-CPU Port Operation
Port Direction
Meaning
Signal
Function
level
Power switch
Low
Power switch "OFF" interruption (H
-+
L:
~)
POO
IN
interruption
High
Power switch "ON" interruption (L
-+
H:
-.r )
Main battery
Low
Inactive
P23
Out
voltage detection
High
Active. Supply main battery voltage to AID
converter
• Supply operational voltage to AID
converter
Low
Reset main CPU, slave CPU, etc.
P40
out
Reset
High
Inactive
Recharging mode
Low
Normal recharging mode
P41
Out
control
High
Trikle recharging mode
P42
Out
Battery back-up
Low
Back-up with main battery
control
High
Back-up with auxiliary battery
Low
Active source input of "P40" and "OFF"
P60
In
Reset switch
High
Inactive
AC adapter (re-
Low
No AC adapter (non recharging condition)
P61
In
charging opera-
tion) detect
High
Recharging condition (AC adapter is plugged)
Recharging mode
Low
Normal recharging mode
P63
Out
for auxiliary bat-
High
Trikle recharging mode
tery
Low
Power ON
P70
Out
Powr ON
High
Power OFF
"OFF" signal for
Low
Active (Initialize the '4C' '6A')
P71
Out
gate array (6A, 4C)
High
Inactive
2-12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents