(2) Inspection
(a) When a MIN cassette tape is inserted.
1 •
o .. ,
2
0.2
(Unit: mm)
The separator must rest on the base plate and there
must be a separation of 0.2 or more between the G
lever and the switch contact plate (approximately
twice the switch contact plate thickness which is 0.1 2.)
lever
(b) When a rug-bent cassette tape is inserted.
0.3-0.5
(Unit: mm)
The separation between the separator and base plate
must be from 0.3
to 0.5 (approximately half or one
third of the separator thickness.)