Advertisement

Micro-
cas-
sette
Shield
board
Disassemble Procedure
Step 1. Remove lower case.
Step 1.
Step 2.
Remove three screws pointed by ar-
rows.
Step 2.
Step 3.
Lift unit up a little horizontally and
next shift unit slightly to right and
lift up unit from left side.
Step 3.
*
Perform the above with FPC cable
being removed.
FPC cable
ToCN3
Step 1.
Step 2.
Step 3.
Remove lower case, board and mi-
Step 1.
crocassette.
Remove four spacers pointed by ar-
rows and two cassette fitting poles.
Step 2.
Lift up shield board slowly.
r
Fig. 4-6
4-4
REV.-A
Assemble Procedure
Place the machine so that the batte-
ry is situated in the right rear corner.
First align the position of right bot-
tom screw, next, top screw, and last,
left bottom screw. Place unit slow-
Iy.
Fit three screws pointed by arrows.
Fig. 4-5
After fitting keyboard, bring down
shield board slowly aligning it to the
hole.
Fit four spacers and two cassette fit-
ting poles.