Specifications - KVH Industries TracVision G6 Installation & Technical Manual

Hide thumbs Also See for TracVision G6:
Table of Contents

Advertisement

TracVision G6 Technical Manual
TracVision G6 GyroTrac
Performance Specifications
TracVision G6 GyroTrac
Environmental Specifications
124
A.2 GyroTrac Compass
Performance Data
Table A-4
Accuracy
Repeatability
Resolution
Tilt Angle/Pitch & Roll Range
Rate Gyro Drift
Maximum Angular Velocity
Bandwidth
Power/Consumption
Data I/O Format
Zero Point Stability
1. After calibration, free magnetic field to tilt angles of ±20˚; accuracy ±5.0
RMS to ±45˚ tilt or roll.
Table A-5
Environmental Data
Operating Temperature
Storage Temperature
Maximum Shock (Performance)
EMI/RFI

Specifications

±3.0° peak; ±1.0° typical
±0.25°
±0.1° (gyro ±0.01)
±45°
0°/minute (auto-corrected)
45°/second
10 Hz
12-32 VDC/330 mA (stand-alone)
TracVision component: 11-16 VDC
3.5 amps nominal, 4.5 amps peak
RS-422 (NMEA 0183 Version 2.2)
±0.8°
-25°C to +55°C (-13°F to +130°F)
-40°C to +85°C (-40°F to +185°F)
20G, 11 msec
IEC 945; FCC Part 15J, Class B
1
54-0161

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents