giving stabilized pitch, roll and yaw data. Data output from Port
1 will be at 4800 baud while data from Ports 2 and 3 will be at
9600 baud; this message may be used in any device capable of
receiving this data rate. The Cetrek proprietary message format is
a stabilized heading output for use with Cetrek autopilots. Each
serial port can be independently programmed to output data at a
rate of 1 Hz to 20 Hz, selectable in 1 Hz increments. The default
data rate is 10 Hz.
Table F-1
NMEA1 Magnetic Heading (HDM)
Communication:
Update rate:
Sentence type:
Sentence breakdown:
Table F-2
NMEA2 Magnetic Heading (HDG)
Communication:
Update rate:
Sentence type:
Sentence breakdown:
4800 baud, 1 start bit, 8 data bits, 1 stop bit,
no parity
Selectable at 1 to 20 Hz (10 Hz default)
$HCHDM,XXX.X,M,* hh <cr> <lf>
HCHDM
NMEA talker and sentence ID
XXX.X
Stabilized magnetic heading in
degrees and tenths
M
Magnetic heading, ASCII hex
0x4D
*
ASCII hex 0x2A
hh
Checksum
cr
Carriage return, ASCII hex 0x0D
lf
Line feed, ASCII hex 0x0A
4800 baud, 1 start bit, 8 data bits, 1 stop bit,
no parity
Selectable at 1 to 20 Hz (10 Hz default)
$HCHDG,XXX.X, *hh <cr> <lf>
HCHDG
NMEA talker and sentence ID
XXX.X
Stabilized magnetic heading in
degrees and tenths
*
ASCII hex 0x2A
hh
Checksum
cr
Carriage return, ASCII hex 0x0D
lf
Line feed, ASCII hex 0x0A