Set RF Tracking Parameters
Function:
sets RF tracking parameter
Command:
@SATCONFIG,X,N,F,S,C,ID,P,B,D<cr>
Response:
Echoes the input data
Where:
@SATCONFIG = directs data to the RF Board
X = satellite location A or B
N = satellite table # (98 & 99 are slots for user-
configured satellites)
F = frequency in MHz (either 00000 or a range from
10700 - 12700)
S = the satellite transponder symbol rate in
Mbit/second (01000 - 29999)
C = the FEC code (e.g., 12, 23, 34, 56, 67, 78)
ID = the satellite network ID in hexidecimal format
(0x####)
P = the LNB polarization (v = vertical,
h = horizontal, r = right, l = left)
B = the LNB down conversion frequency (l = low,
h = high, G = Latin America, U = USA)
D = decoding type (0 = test, 1 = DSS-A,
2 = DSS-B, 3 = DVB)
ID Match/Decoded Network ID
Function:
report ID match and decoded network ID
Command:
@CHECKID
Response:
Y,0X####
N,0X####
Y,NoID
N,NoID
Where:
Y = yes
N = no
0X#### = network ID
NoID = satellite unidentified