3.5

STOP push-button wiring

Wire the STOP push-button to 2 and 4 terminals on JP4 terminal block.
Additional STOP controls/push-buttons can be wired in parallel (N.C. contact)
The wiring of an emergency stop push-button is highly
recommended for the safety of people and objects.
Note:
Should you need to temporary exclude the STOP connections, please
set
parameter in the ACCESSORIES menu to
3.6

PHOTOCELLS wiring

3.6.1 CLOSING Photocells
Power the CLOSING PHOTOCELLS wiring them to terminals
7 - 8 - 9 on JP5 terminal block.
Wire the N.C. contact of the photocells to terminals 5 - 7 on JP5
terminal block.
The closing photocells will behave as follows:
If an obstacle interrupts the photocell beam when the
gate is closing, the automation STOPS and REVERSES in
about 1.5 seconds.
An obstacle detected by the photocells when the gate is
OPENING does not cause any effect.
Additional sets of CLOSING PHOTOCELLS can be wired in series
(N.C. contact).
For safety reasons al least one set of photocells must be installed
to protect the CLOSING area of the gate.
Note:
Should you need to temporary exclude the CLOSING
PHOTOCELLS connections, please set
in the ACCESSORIES menu to
3.6.2 OPENING Photocells
Power the OPENING PHOTOCELLS wiring them to terminals
7 - 8 - 9 on JP5 terminal block.
Wire the N.C. contact of the photocells to terminals 6 - 7 on
JP5 terminal block.
The opening photocells will behave as follows:
If an obstacle interrupts the photocell beam when gate is
opening, the automation STOPS. Once the obstacle has
been removed the gate CONTINUES to open.
Additional sets of OPENING PHOTOCELLS can be wired in series
(N.C. contact).
For safety reasons al least one set of photocells must be installed
to protect the OPENING area of the gate.
Note:
Should you need to temporary exclude the OPENING
PHOTOCELLS connections, please set
in the ACCESSORIES menu to
Q80A_8_2017
PROTECO S.r.l.
Via Neive, 77 - 12050 Castagnito (CN) ITALY
=DISABLED.
parameter
=DISABLED.
parameter
=DISABLED.
Tel. +39 0173 210111 - Fax +39 0173 210199
JP5
JP4
1
2
3
4
5
6
7
RF40
TX
RX
1
2
3
4
5
6
7
8
JP4
JP5
RF40
TX
RX
1
2
3
4
5
6
7
8
JP4
JP5
info@proteco.net - www.proteco.net
JP6
8
9
10 11
1 2
3
Jumper
9
10 11
JP6
1 2
3
Jumper
9
10 11
JP6
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents