SEQUENTIAL programming mode

This step-by-step programming procedure allows you full control of each setting and finer professional adjustments.
If the control panel is programmed using this procedure, obstacle detection function
is automatically disabled.
IMPORTANT:
Please check first that motors force (default setting level is 7 in a 1 to 10 range) is suitable to the
leaves' weight.
In case of very light or very heavy gates please adjust
accordingly before carry-out any programming procedure: the leave shouldn't stop if a light force is opposed.
- If possible is better to program the control unit when motors are cold (not after repeated use)
- The gate must have opening and closing ground stops for a correct SEQUENTIAL programming procedure.
You can program the control panel with the sequential procedure using button
or using a remote control previously saved.
1
Use
2
Press button
Press the remote control (or button
3
• Leaf 1 starts opening.
4
When Leaf 1 is about to 90% of the opening path, press again the remote control
(or button
• Leaf one decelerates and continues opening.
5
Once Leaf 1 has reached the fully open position, wait 4 - 5 seconds and then press
again the remote control (or button
The working parameters for Leaf 1 have been set. The display now shows:
Repeat steps 3, 4, 5 of this procedure to set working times for Leaf 2 too.
6
7
Now working times, deceleration times and the level of sensibility for obstacle detection
have been automatically set.
If
and
settings are changed once programming is completed, you need to re-start AUTOMATIC
programming procedure again.
15
PROTECO S.r.l.
Via Neive, 77 - 12050 Castagnito (CN) ITALY
buttons to move inside the menu, till the display shows:
to confirm. The display shows:
on the control panel).
on the control panel).
Tel. +39 0173 210111 - Fax +39 0173 210199
and
).
settings in
FORCE menu
on the control panel
info@proteco.net - www.proteco.net
Q80A_8_2017

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents