JP1 = AERIAL terminal block
21
aerial cable (SIGNAL)
22
aerial cable (EARTH)
JP2 = TRANSFORMER secondary plug 24Vac (red wires)
JP3 = TRANSFORMER main plug 230Vac (black wires)
JP4 = CONTROLS terminal block
1
START command (N.O. contact)
2
STOP command (N.C. contact)
3
PEDESTRIAN START command (N.O. contact)
4
NEUTRAL for controls
JP5 = PHOTOCELLS and SAFETY DEVICES
5
CLOSING PHOTOCELLS terminal (N.C. contact)
6
OPENING PHOTOCELLS terminal (N.C. contact)
7
Photocells RECEIVER power supply -24V
8
Photocells RECEIVER/TRANSMITTER
9
Photocell TRANSMITTER power supply -24V
JP6 = BLINKER terminal block
10
BLINKER power supply 24Vac
11
BLINKER power supply 24Vac
JP7 = MOTOR 1(M1) terminal block
12
OPENING
13
NEUTRAL
terminal MOTOR M1
14
CLOSING
JP8 = MOTOR 2 (M2) terminal block
15
OPENING
16
terminal MOTOR M2
NEUTRAL
17
CLOSING
JP9 = 230V MAIN POWER/EARTH terminal block
Pole disconnect means must be incorporated in the fixed
wiring to the control panel
J5 = plug for optional modules
5
PROTECO S.r.l.
Via Neive, 77 - 12050 Castagnito (CN) ITALY
Tel. +39 0173 210111 - Fax +39 0173 210199
22
JP1
21
JP2
JP3
JP4
1
2
3
4
JP5
5
6
7
8
9
JP6
10 11
FLASH
24V ac
JP7
JP8
12 13 14
15 16 17
M1
M2
PED
JP9
18
19
20
P
N
F
J5