Operating Procedure Guidelines

1-5
Operating Procedure Guidelines
Setting Counter Type
1, 2, 3...
The DIP switch at the front of the Unit can be used to operate every Counter as
Simple Counter or as Circular/Linear Counter. Setting the DIP switch in the appro-
priate position defines the Counter Type.
The Operation Procedure Guidelines consists of 5 steps. In step 1 of the
Operating Procedure Guidelines for every Counter the Type has to be set with
the DIP switch into one of the following configurations:
Configuration 1
All Counters as Simple Counter
Configuration 2
All Counters as Circular/Linear Counter
Configuration 3
Mixed configuration of Simple/Circular/Linear Counters
Next you must execute step 2, 3, 4, and 5. Once the I/O table is created in step 5,
the Unit must be configured if you have chosen for Configuration 2 or 3. If you have
chosen for Configuration 1 the Unit is ready to operate. Consequently guidelines
to be followed after step 5 will depend on the Configuration made in step 1.
1. Set the Counter Type for every Counter at the front of the Unit. Pins 1 and 2
correspond to Counters 1 and 2. Refer to 2-1-3 "Counter Type Switch" for fur-
ther details.
2. Set the Machine Number. Refer to 2-1-4 "Machine Number Switch" for further
details.
Counter Type Switch:
ON
OFF
OFF = Simple Counter
ON = Circular/Linear Counter
Machine Number Switch:
MACH
No.
×
1
10
×
0
10
Set between 00 - 92
Section 1-5
21