Extra Functions

3-7

Extra Functions

3-7-1

Programmable Output Pulses

Unit Output Pattern:
Rising edge Output (0-1)
Corresponding Digital Output (0-1):
Normal Functionality
Output Pulse ON-Delay
Output Pulse Duration
Output Pulse
ON-Delay and Duration
Normal Functionality
Output Pulse ON-Delay
Output Pulse Duration
Depending on the requirements of your application, the timing characteristics of
the two Digital Outputs of the High-speed Counter Unit can be modified. The Unit
can be either in Range Mode or in Comparison Mode. The following functionality
can be assigned to the Digital Outputs:
Normal Functionality (= default)
Output Turn ON Delay [1 ms to 9999 ms], to delay turning ON an Output
Output Pulse Duration [1 ms to 9999 ms], to generate an Output pulse of a
specified duration
Combination of Output Turn ON Delay + Output Pulse Duration
The corresponding action is triggered by a rising edge of the Output (0-1) of the
Unit Output Pattern and consequently applied to the corresponding Digital Output.
31
31 30 29
ON-Delay
Pulse Duration
ON-Delay
Pulse Duration
A Digital Output that is configured to have Normal Functionality will turn ON imme-
diately after the corresponding bit of the Unit Output Pattern turns ON.
A Digital Output that is configured to have an Output Pulse ON-Delay will turn ON
after the ON-Delay has elapsed.
A Digital Output that is configured to have an Output Pulse Duration turns ON
immediately and will stay ON for the specified Pulse Duration. After the Pulse
Duration has elapsed the Digital Output turns OFF.
16 15 14
6
ON-Delay
Pulse Duration
ON-Delay
Pulse Duration
Section 3-7
4
3
2
1
0
5
4
3
2 O1 O0
Reset ON-Delay
ON-Delay
Pulse Duration
Reset ON-Delay
ON-Delay
time