Omron CJ1W-CT021 Operation Manual page 181

High-speed counter units
Hide thumbs Also See for CJ1W-CT021:
Table of Contents

Advertisement

CAM-positioning
Range Data Counter 1
Range Data Counter 1
Range 0 settings of
Range 1 settings of
Range 2 settings of
Range 3 settings of
Range 4 settings of Counter 1 (in EM):
Counter 1 (in EM):
EM 00100
0
1
F
EM 00101
0
0
0
EM 00102
0
3
2
EM 00103
0
0
0
EM 00104
1
0
2
EM 00105
0
0
0
Counter 1 (in EM):
EM 00106
0
2
B
EM 00107
0
0
0
EM 00108
0
5
D
EM 00109
0
0
0
EM 00110
6
1
6
EM 00111
0
0
0
Counter 1 (in EM):
EM 00112
0
9
C
EM 00113
0
0
0
EM 00114
1
7
7
EM 00115
0
0
0
EM 00116
0
2
A
EM 00117
0
0
0
Counter 1 (in EM):
EM 00118
1
3
8
EM 00119
0
0
0
EM 00120
1
B
5
EM 00121
0
0
0
EM 00122
0
0
0
EM 00123
0
0
0
EM 00124
2
E
E
EM 00125
0
0
0
EM 00126
4
6
5
EM 00127
0
0
0
EM 00128
0
E
8
EM 00129
0
0
0
Transfer the DM-settings to the High-speed Counter Unit by restarting the Unit.
4
Lower Range Limit is 500 (=000001F4
0
0
Upper Range Limit is 800 (=00000320
0
3
Output Pattern: 0, 1, 5 and 12 are ON (=00001023
0
C
Lower Range Limit is 700 (=000002BC
0
C
Upper Range Limit is 1500 (=000005DC
0
0
Output Pattern:
5, 6, 8, 13 and 14 are ON (=00006160
0
4
Lower Range Limit is 2500 (=000009C4
0
0
Upper Range Limit is 6000 (=00001770
0
0
Output Pattern:
5, 7 and 9 are ON (=000002A0
0
8
Lower Range Limit is 5000 (=00001388
0
8
Upper Range Limit is 7000 (=00001B 58
0
C
Output Pattern:
2 and 3 are ON (=0000000C
0
0
Lower Range Limit is 12000 (=00002EE0
0
0
Upper Range Limit is 18000 (=00004650
0
0
Output Pattern:
7, 9, 10 and 11 are ON (=00000E80
0
Section 6-4
)
H
)
H
)
H
)
H
)
H
)
H
)
H
)
H
)
H
)
H
)
H
)
H
)
H
)
H
)
H
161

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents