Pulse current 0 - I
.
INV.
An output signal is obtained, which is proportional
to the output current in the interval 0 - I
Pulse power 0 - P
.
M,N
An output signal is obtained, which is proportional to
the present output power. Par. 342 corresponds to
the value set in parameter 102 Motor power, P
Pulse temperature 0 - Temp.
An output signal is obtained, which is proportional to
the present heatsink temperature. 0 Hz corresponds
to a heatsink temperature of less than 20° C, and
parameter 342 corresponds to 100° C.
NB!:
Output terminal 46 is not available on
DeviceNet. Minimum output frequency at
frequency output = 16 Hz
342 Terminal 46, max. pulse scaling
(DO 46 MAX. PULS)
Value:
150 - 10000 Hz
Function:
This parameter is used for setting the pulse
output signal's maximum frequency.
Description of choice:
Set the required frequency.
343 Precise stop function
(PRECISE STOP)
Value:
Precise ramp stop (NORMAL)
Counter stop with reset
(COUNT STOP RESET)
Counter stop without reset
(COUNT STOP NO RESET)
Speed-compensated stop (SPD CMP STOP)
Speed-compensated counter stop with reset
(SPD CMP CSTOP W. RES)
Speed-compensated counter stop without reset
(SPD CMP CSTOP NO RES)
Function:
In this parameter you select which stop function is
performed in response to a stop command. All six
data selections contain a precise stop routine, thus
ensuring a high level of repeat accuracy.
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.28.E9.02 - VLT is a registered Danfoss trademark
.
INV
.
M,N
.
MAX
5000 Hz
[0]
[1]
[2]
[3]
[4]
[5]
®
VLT
2800 Series
The selections are a combination of the
functions described below.
NB!:
Pulse start [8] may not be used together
with the precise stop function.
Description of choice:
Precise ramp stop [0] is selected to achieve high
repetiti v e precision at the stopping point.
Counter stop. Once it has recei v ed a pulse start
signal the frequency converter runs until the number of
pulses programmed by the user have been recei v ed at
input terminal 33. In this way an internal stop signal will
acti v ate the normal ramp down time (parameter 208).
The counter function is acti v ated (starts timing) at
the flank of the start signal (when it changes
from stop to start).
Speed compensated stop. To stop at precisely
the same point, regardless of the present speed,
a stop signal recei v ed is delayed internally when
the present speed is lower than the maximum
speed (set in parameter 202).
Reset. Counter stop and Speed-compensated stop
can be combined with or without reset.
Counter stop with reset [1]. After each precise
stop the number of pulses counted during
ramp down 0 Hz is reset.
Counter stop without reset [2]. The number of pulses
counted during ramp down to 0 Hz is deducted
from the counter value in parameter 344.
344 Counter value
(PULSE COUNT PRE.)
Value:
0 - 999999
Function:
In this parameter you can select the counter
value to be used in the integrated precise stop
function (parameter 343).
Description of choice:
The factory setting is 100000 pulses. The highest
frequency (max. resolution) that can be registered
at terminal 33 is 67.6 kHz.
100000 pulses
95