Final Checklist; Gas Supply; Operation - DCS RDV2 Installation Instructions Manual

Professional range
Table of Contents

Advertisement

Available languages

Available languages

TO BE COMPLETED BY THE INSTALLER
GENERAL
Placement of unit.
Specified clearance maintained to cabinet surfaces.
Unit Level - front to back, side to side.
All packaging material and tie straps removed.
Backguard attached if there is less than 6" (152mm) clearance to combustibles behind unit.
Radiant tray placed in grill unit (if equipped). The grill grate is in place.
ELECTRICAL
Receptacle with properly rated over-current protection is provided for service cord
connection.
Adequate ground connection.
Front kick panel in place and two screws secure.

GAS SUPPLY

Connection: 1/2 NPT with a minimum 5/8" diameter flex line. Site gas supply is compatible
with range model, and sufficient pressure is available (see section 'Gas connection').
The pressure regulator which is connected to the manifold is set for 5.0" W.C. for natural
gas or 10.0" W.C. for LP.
Manual gas shut-off valve installed in an accessible location.
Unit tested and free of gas leaks.
Complete and keep for safe reference:
Model
Serial No.
Purchase Date
Purchaser
Dealer Address
Installer's Name
Installer's Signature
Installation Company
Installation Date
@2

FINAL CHECKLIST

OPERATION

All internal packing materials removed. Check below the grate and inside the oven.
If used on LP gas, verify that pressure regulator, orifice hoods, air shutters, and valve
have been set for use with LP gas.
Grill grate is seated and does not rock (if equipped).
Knobs turn correctly and freely.
Each burner lights satisfactorily, both individually and with other burners operating at
the same time.
Flame adjustment made on air shutter of each oven, griddle, or grill burner.
Griddle is level and does not rock (if equipped).
Oven door hinges seated and door opens and closes properly.
Burner pan supports correctly positioned, level, and do not rock.
Griddle flame correct.
Grill flame correct.
Cooktop burner flame correct.
Copyright © Fisher & Paykel Appliances 2016. All rights reserved.
The product specifications in this booklet apply to the specific products
and models described at the date of issue. Under our policy of continuous
product improvement, these specifications may change at any time. You
should therefore check with your Dealer to ensure this booklet correctly
describes the product currently available.
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rgv2Rgcv2

Table of Contents