Download Print this page

Installer Final Checklist - DCS RGSC-305SS Installation Manual

Professional 30" self-clean gas range
Hide thumbs Also See for RGSC-305SS:

Advertisement

Available languages

Available languages

INSTALLER FINAL CHECKLIST
GENERAL
,I
Placement of Unit.
,I
Specified clearance maintained
to cabinet surfaces.
_1 Unit Leve[- front to back, side to side.
_1 A[[ packaging
material and tie straps removed, drip pans dean and empty.
_1 Backguard
wall[ system instaHHedif there is Hessthan 12" cHearance above the cooking
surface
to combustibHes behind unit.
ELECTRICAL
_1
Receptacle with 15 ampere over-current
protection
is provided
for service cord connection.
,I
Adequate
ground
connection.
_1 Kick pane[ (See Fig.6, page 7)in place and two (2) screws secure.
GAS SUPPLY
_1 Connection:
1/2 NPT with a minimum
5/8" diameter
metal flex Nine.
_1 The pressure regulator
which is connected
to the manifoHd is set for 5.0" W.C. for natural gas
or 10.0" W.C.for LR
_1 Manual gas shut offvalve
installed in an accessible location.
,I
Unit tested and free of gas leaks.
OPERATION
_1 All internal
packing
materials removed.
Check below grate and inside oven.
_1 Bezels centered
on burner knobs and knobs turn freely.
_1 Each burner lights satisfactorily,
both individually
and with other burners operating
at the
same time.
_1
Check flame characteristics
on all burners and adjust as specified
per instructions
on page 12
(See Figs. 15-17, page 12).
,I Oven door hinges seated and door opens and doses properly.
_I Burner gratescorrectly p ositioned, l evel, and do not rock.
14