IMPORTANT!
This range must be connected to the mains
power supply only by a suitably qualified person.
This range must be earthed.
Always disconnect electric supply cord from the
wall outlet or service disconnect before servicing
this appliance.
Observe all governing codes and ordinances
when grounding, in absence of which, observe
National Electrical Code ANSI / NFPA No. 70.
RGV2 & RGCV2 MODELS
The electrical supply must be a correctly polarized 120 V AC, 60 Hz, single phase circuit
suitable for the maximum current draw of the model, as detailed in the table below.
Please verify your model's current draw by checking the rating label on the back of the
range.
MODEL
MAX. CURRENT DRAW
RGCV2-305
5 A
RGV2-364GD
8 A
5 A
RGV2-304
5 A
RGV2-366
9 A
RGV2-488
RGV2-485GD
15 A
RGV2-486GD
12 A
RGV2-486GL
12 A
Required grounding method – RGV2 & RGCV2 MODELS
This appliance is factory equipped with a power supply cord with a three-prong
grounding plug (with polarized parallel blades). It must be plugged into a mating
grounding-type receptacle, connected to a correctly polarized 120 volt circuit. If the
circuit does not have a grounding type receptacle, it is the responsibility and obligation
of the installer to have the existing receptacle changed to a properly grounded and
polarized receptacle in accordance with all applicable local codes and ordinances by
a qualified electrician. In the absence of local codes and ordinances, the receptacle
replacement shall be in accordance with the National Electrical Code.
IMPORTANT!
The third prong should not, under ANY circumstances, be cut or removed.
16
!4

ELECTRICAL CONNECTION

The rating
label is located
on the back of
the range
A wiring
Wiring diagrams
diagram label
are also in the
is attached to
service summary,
the back of
attached to the
the range
inside of the kick
panel
CIRCUIT
15 A
Receptacle Box
Cover Plate
15 A
15 A
Three
Prong
15 A
Plug
15 A
15 A
15 A
15 A
Three Prong
Receptacle
RDV2 MODELS
The electrical supply must be a correctly polarized 120/240 volt, 3-wire (plus ground),
60 Hz circuit suitable for the maximum current draw of the model, as detailed in the table
below. Please verify your model's current draw by checking the rating label on the back of
the range.
The power receptacle must be a NEMA 14-50 device to accept the four prong plug supplied
with the unit. The receptacle should be located within the area shown on opposite page.
MODEL
MAX. CURRENT DRAW
18 A
RDV2-305
RDV2-304
21 A
RDV2-364GD
21 A
RDV2-366
18 A
RDV2-488
33 A
RDV2-485GD
40 A
RDV2-486GD
36 A
RDV2-486GL
36 A
Required grounding method – RDV2 MODELS
This appliance is factory equipped with a power supply cord with a four-prong grounding
plug. It must be plugged into a mating grounding, type receptacle, connected to a correctly
polarized 120/240 volt circuit. If the circuit does not have a grounding type receptacle, it is
the responsibility and obligation of the installer to have the existing receptacle changed to
a properly grounded and polarized receptacle in accordance with all applicable local codes
and ordinances by a qualified electrician. In the absence of local codes and ordinances, the
receptacle replacement shall be in accordance with the National Electrical Code.
IMPORTANT!
The fourth prong (round grounding pin) should not, under any circumstances, be cut or
removed.
Connecting to an electrical system utilizing a single conductor for ground and neutral
The range is equipped for use with an electrical supply which uses a separate grounding
conductor (4 wire system). If this range must be connected to an electrical system which
utilizes a single conductor for ground and neutral (3 wire system), the grounding jumper at
the terminal block must be connected. The grounding jumper is located behind the front
kickpanel.
To connect grounding jumper:
Disconnect restraining clip holding jumper.
Connect green jumper to open terminal on
neutral (white) portion of the terminal block,
as shown
CIRCUIT
Electrical Supply
30 A
30 A
30 A
30 A
50 A
50 A
50 A
NEMA 14-50
Receptacle
50 A
Green
Red
White
Black
Connect Here
Terminal Block
RDV2 terminal block

Advertisement