Page 1
THE RDS PROFESSIONAL RANGE Installation Guide MODELS: RDS-305 RDS-364GD RDS-486GL RDS-484GG RDS-366 RDS-486GD RDS-364GL RDS-485GD...
Page 2
A MESSAGE TO OUR CUSTOMERS Thank you for selecting this DCS RDS Range. Because of this appliance’s unique features we have developed this Installation Guide. It contains valuable information on how to properly install your new appliance for years of safe and enjoyable cooking.
INTRODUCTION DCS Professional Ranges are designed with a number of features and are available in a multitude of different combinations: top burner sections, thermostatic griddles, and grills. Ranges are available in 30” , 36” , and 48” widths. The large capacity electric ovens of the Dual Fuel Range are self-cleaning and convection.
PLANNING THE INSTALLATION RECOMMENDED INSTALLATION INSTRUCTION Install components in the following order: A) Vent Hood B) Backguard System C) Range 1) Locate and level range according to range installation instructions. 2) Measure distance from floor to top of island trim on range, adding 1/8” for backguard clearance. 3) Transfer this measurement to the wall.
Page 7
UNPACKING AND HANDLING CAUTION: Proper equipment and adequate manpower must be used in moving the range to avoid damage to the unit or the floor. The unit is heavy and rests on adjustable steel legs. WARNING: DO NOT lift range by the oven door handles!! WARNING: DO NOT remove the grill or griddle assemblies!! It may be necessary to remove the oven doors and...
Page 8
UNPACKING AND HANDLING MOVING AND PLACING THE RANGE Electric and gas connections should be made before the range is slid into the cabinet opening (see page 13 & 14). If installing a full backguard with the range, it should also be installed before the range is placed in its final position (refer to page 5).
VENTILATION REQUIREMENTS STEP 2: A suitable exhaust hood must be installed above the range. The following chart indicates the minimum blower capacity recommended for hood ventilation. VENTILATION STANDARD COUNTER ISLAND UNIT INSTALLATION INSTALLATION RECOMMENDATIONS RECOMMENDATIONS HOOD (24" Deep x Unit Width) (30"...
1/4” 1/2” 5/8” tip bracket to the floor and wall. The use of Model this bracket does not preclude tipping of RDS-305 RDS-36 RDS-48 Series the range when not properly installed. WOOD CONSTRUCTION: Place the bracket against the back wall, into the right WARNING rear corner where the range is to be located.
1) The range is a free standing unit. If the unit is to be placed adjacent to cabinets, the clearances shown in fig. 8 (RDS-36 & 48) & fig. 9 (RDS-305) are required. The same clearances apply to island installations.
Page 12
“National Fuel Gas Code” (ANSI Z223.1, Latest Edition). The range height is adjustable. The level of the range top must be at the same level or above the countertop level. Fig. 9 RDS-305 Models Only Gas Supply Manual Shut-Off Valve must be Easily Accessible 2"...
The range height is adjustable. The level of the range top must be at the same level or above the countertop level. Fig. 11 All RDS Models Product / Installation Clearance Specifications RDS-48 Models RDS-36 Models RDS-305 Models RDS-48 Models 28-1/8” 10-1/8” 2”...
10. NEMA 14-50 NEMA 14-50 Receptacle Receptacle RDS-305 MODEL The electrical supply must be a 120/240 volt, 3 Fig. 13 wire (plus ground), 60 Hz, 30 AMP circuit. The power receptacle must be a NEMA 14-50 device to accept the four prong plug supplied with the unit.
ELECTRICAL / GAS CONNECTIONS STEP 5: (CONTINUED) RECOMMENDED GROUNDING METHOD This appliance is factory equipped with a power supply cord with a four-prong grounding plug. It must be plugged into a mating grounding, type receptacle, connected to a correctly polarized 120/240 volt circuit.
Page 16
HOOK-UP TO GAS SUPPLY STEP 6: (CONTINUED) CAUTION: The appliance must be isolated from the building’s gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5kPa.).
STEP 7: WARNING For Warranty coverage, DCS requires that burner adjustments be made by a qualified technician at the time of installation. Extreme care should be u s e d when adjustments are made after installation. Improper or lack of adjustments will void your warranty.
INSTALLER FINAL CHECKLIST GENERAL Placement of unit. Specified clearance maintained to cabinet surfaces. Unit Level - front to back, side to side. All packaging material and tie straps removed, drip pans clean and empty. Backguard attached if there is less than 12" clearance above the cooking surface to combustibles behind unit.
HOW TO OBTAIN SERVICE For warranty service, contact DCS Customer Service at (888) 281-5698. Before you call, please have the following information ready: Model Number Serial Number Date of installation A brief description of the problem Your satisfaction is of the utmost importance to us. If a problem cannot be resolved to your...
DCS to be defective. Replacement will be F.O.B. DCS, and DCS will not be liable for any transportation costs, labor costs, or export duties. This warranty shall not apply, nor can we assume responsibility for damage that might...
Page 30
5800 Skylab Road, Huntington Beach, CA 92647 Tel: 714.372.7000 • Fax: 714.372.7001 Customer Service: (888) 281-5698 www.dcsappliances.com As product improvement is an ongoing process at DCS, we reserve the right to change specifications or design without notice. P/N 17435 Rev. B...