Siemens CPU 948 Programming Manual page 477

Simatic s5 s5-155u
Table of Contents

Advertisement

FB 100 continued:
0013
:
0014
:SLW
2
0015
:T
FY 245
0016
:
0017
:L
KB 1
0018
:T
FY 244
0019
:
001A LOOP :L
FY 245
001B
:L
FY 244
001C
:+F
001D
:T
FW 240
001E
:ADD
BN+16
001F
:T
FW 242
0020
:
0021
:DO
0022
:L
DR 0
0023
:T
FY 239
0024
:L
KB 0
0025
:!=F
0026
:JC
=EMPT
0027
:
0028
:B
FW 242
0029
:L
DL 0
002A
:T
FY 246
002B
:L
KB 246
:JU
OB 203
002C
002D
:L
FY 248
002E
:JC
=OBER
002F
:
0030
:L
FY 249
0031
:L
FY 239
0032
:><F
0033
:JC
=EMPT
0034
:
0035
:L
KB 0
0036
:T
FY 249
0037
:
0038
:B
FY 240
0039
:L
DW 0
003A
:T
FW 247
003B
:
003C TRAN :L
KB 246
:JU
OB 202
003D
003E
:L
FY 250
003F
:JC
=OBER
0040
:
0041
:L
FY 249
0042
:I
1
0043
:T
FY 249
0044
:L
FY 239
0045
:<F
0046
:JC
=TRAN
0047
:
CPU 948 Programming Guide
C79000-G8576-C848-04
FW 242
CPUN = CPUN * 4
Base address
Link counter
Base address
+ counter
+ offset
Number of reserved
fields = 0 ?
No. of the receiving CPU
SF OB:
"Test sending capacity"
Abort if error
Transmitting capacity >< no.
of reserved fields?
Field counter
Type and number of
the source DB
SF OB:
Send a data field
Abort if error/warning
Field no. = field no. + 1
All data fields transferred?
Continued on the next page
Applications
10 - 73

Advertisement

Table of Contents
loading

Table of Contents