Multiprocessor Communication
Errors
10 - 28
Cond.
code
byte
Table 10-3 continued:
41
The assignment list in the data block is not correctly
structured.
42
The sum of the assigned memory fields is greater than 48.
If an error occurs, you must change the program/parameters.
Error numbers (evaluation of the condition code byte as a byte):
Table 10-4
Condition code byte: Error numbers
Cond.
code
byte
65
The parameter "receiving CPU" (SEND, SEND TEST)
is illegal. The following errors are possible:
- The number of the receiving CPU is greater than 4,
- the number of the receiving CPU is less than 1,
- the number of the receiving CPU is the same as the
CPU's own number.
66
The parameter "transmitting CPU" (RECEIVE, RECEIVE
TEST) is illegal. The following errors are possible:
- The number of the transmitting CPU is greater than 4,
- the number of the transmitting CPU is less than 1,
- the number of the transmitting CPU is the same as the
CPU's own number.
67
The special function organization block call is wrong
(SEND, RECEIVE, SEND TEST, RECEIVE TEST). The
following errors are possible:
- Secondary error, since the INITIALIZE function could
not be called or was terminated by an initialization
conflict.
- Double call: the call for this function (SEND, SEND
TEST, RECEIVE or RECEIVE TEST) is illegal,
since one of these functions INITIALIZE, SEND,
SEND TEST, RECEIVE or RECEIVE TEST has
already been called in this CPU in a lower
processing level (i.e. cyclic program execution).
- The CPU's own number is incorrect (system data
corrupted); following power down/power up the CPU
number is generated again by the system program.
Significance
Significance
CPU 948 Programming Guide
C79000-G8576-C848-04