Operating And Storage Parameters; Supported Environmental Standards - Cisco ASR 5000 Series Installation Manual

Hide thumbs Also See for ASR 5000 Series:
Table of Contents

Advertisement

▀ Operating and Storage Parameters

Operating and Storage Parameters
Use the following information to plan your network installation for the ASR 5000 platform.
Table 106. Temperature, Humidity and Altitude Recommendations
Temperature
Operating
Storage
Humidity
Operating
Storage
Altitude
Operating
Non-operating

Supported Environmental Standards

The system has been successfully tested against the following environmental standards:
 Operational Thermal, Operating Conditions - GR-63 Criteria [72, 73]
 Airborne Contaminants, Indoor Levels - GR-63 Criterion [125]
 Operational Thermal, Short-term Conditions - GR-63 Criteria [72, 73]
 Storage Environments, and Transportation and Handling - GR-63 Criteria [69-71, 107-109, 124]
 Earthquake Zone 4 - GR-63 Criteria [110-112, 114, 115, 117, 119]
 Airborne Contaminants, Outdoor Levels - GR-63 Criteria [126, 127]
 Altitude - GR-63 Criteria [74, 76]
 Thermal Heat Dissipation - GR-63 Criteria [77-79]
 Acoustic Noise - GR-63 Criterion [128]
 ESTI 300 019 - Environmental conditions and environmental tests for telecommunications equipment
▄ ASR 5000 Installation Guide
282
0 degrees C to +55 degrees C
-40 degrees C to +70 degrees C
20 to 80 percent non-condensing
10 to 95 percent non-condensing
197 ft. (60m) below to 13,123 ft. (4,000m) above sea level
197 ft. (60m) below to 49,212 ft. (15,000m) above sea level
Environmental Specifications