B.4 MEMORY MAPPING
Value
IEC 61850 GOOSE Rx dataset
item
174
GGIO3.ST.UIntIn5.q
175
GGIO3.ST.UIntIn5.stVal
176
GGIO3.ST.UIntIn6.q
177
GGIO3.ST.UIntIn6.stVal
178
GGIO3.ST.UIntIn7.q
B
179
GGIO3.ST.UIntIn7.stVal
180
GGIO3.ST.UIntIn8.q
181
GGIO3.ST.UIntIn8.stVal
182
GGIO3.ST.UIntIn9.q
183
GGIO3.ST.UIntIn9.stVal
184
GGIO3.ST.UIntIn10.q
185
GGIO3.ST.UIntIn10.stVal
186
GGIO3.ST.UIntIn11.q
187
GGIO3.ST.UIntIn11.stVal
188
GGIO3.ST.UIntIn12.q
189
GGIO3.ST.UIntIn12.stVal
190
GGIO3.ST.UIntIn13.q
191
GGIO3.ST.UIntIn13.stVal
192
GGIO3.ST.UIntIn14.q
193
GGIO3.ST.UIntIn14.stVal
194
GGIO3.ST.UIntIn15.q
195
GGIO3.ST.UIntIn15.stVal
196
GGIO3.ST.UIntIn16.q
197
GGIO3.ST.UIntIn16.stVal
F237
ENUMERATION: REAL TIME CLOCK MONTH (FOR EXAMPLE,
DAYLIGHT SAVINGS TIME)
Value
Month
0
January
1
February
2
March
3
April
4
May
5
June
6
July
7
August
8
September
9
October
10
November
11
December
F238
ENUMERATION: REAL TIME CLOCK DAY (FOR EXAMPLE,
DAYLIGHT SAVINGS TIME)
Value
Day
0
Sunday
1
Monday
2
Tuesday
3
Wednesday
B-64
Value
F239
ENUMERATION: REAL TIME CLOCK DAYLIGHT SAVINGS
TIME START DAY INSTANCE
Value
F245
ENUMERATION: TEST MODE FUNCTION
Value
F250
ENUMERATION: B90 PRODUCT FUNCTION
0 = Logic, 1 = Protection
F300
UR_UINT16: FLEXLOGIC™ BASE TYPE (7-bit type)
The FlexLogic™ BASE type is 7 bits and is combined with an 8-bit
descriptor and 1 bit for protection element to form a 16-bit value.
The combined bits are of the form: PTTTTTTTDDDDDDDD,
where P bit if set, indicates that the FlexLogic™ type is associated
with a protection element state and T represents bits for the BASE
type, and D represents bits for the descriptor.
The values in square brackets indicate the base type with P prefix
[PTTTTTTT] and the values in round brackets indicate the descrip-
tor range. The right-most T bit indicates whether the type is an ON
or OFF type. There can be a total of 64 types (plus protection ele-
ments). There can be a total of 256 descriptors of each type.
[0] Off (0) – this is boolean FALSE value
[1] On (1) – this is boolean TRUE value
[2] CONTACT INPUTS (1 to 96)
[3] CONTACT INPUTS OFF (1 to 96)
[4] VIRTUAL INPUTS (1 to 32)
[6] VIRTUAL OUTPUTS (1 to 64)
[8] CONTACT OUTPUTS
[10] CONTACT OUTPUTS VOLTAGE DETECTED (1 to 64)
[11] CONTACT OUTPUTS VOLTAGE OFF DETECTED (1 to 64)
[12] CONTACT OUTPUTS CURRENT DETECTED (1 to 64)
[13] CONTACT OUTPUTS CURRENT OFF DETECTED (1 to 64)
[14] REMOTE INPUTS (1 to 32)
[16] DIRECT INPUTS (1 to 96)
B90 Low Impedance Bus Differential System
Day
4
Thursday
5
Friday
6
Saturday
Instance
0
First
1
Second
2
Third
3
Fourth
4
Last
Function
0
Disabled
1
Isolated
2
Forcible