GE B90 Instruction Manual page 338

Ur series low impedance bus differential system
Hide thumbs Also See for B90:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 6 of 44)
ADDR
REGISTER NAME
332A
Session Lockout Period
332B
Reserved
Security Supervisory (Read/Write Setting)
3331
Local Authentication Enable
3332
Supervisor Role Enable
B
3333
Lock Relay
3334
Factory Service Mode Enable
3335
Failed Authentication Alarm Enable
3336
Firmware Lock Alarm
3337
Settings Lock Alarm
Security Command (Read/Write Command)
3339
Operator Logoff
333A
Engineer Logoff
333B
Administrator Logoff
333C
Clear Security Data
Event Recorder (Read Only)
3400
Events Since Last Clear
3402
Number of Available Events
3404
Event Recorder Last Cleared Date
Event Recorder Commands (Read/Write Command)
3406
Event Recorder Clear Command
Expanded Direct Input/Output Status (Read Only)
3560
Direct Device States, one per register (16 items)
3570
Direct Input States, one per register (96 items)
Passwords (Read/Write Command)
4000
Command Password Setting
Passwords (Read/Write Setting)
4002
Setting Password Setting
Passwords (Read/Write)
4008
Command Password Entry
400A
Setting Password Entry
Passwords (Read Only Actual Values)
4010
Command Password Status
4011
Setting Password Status
Passwords (Read/Write Settings)
4012
Command Password Access Timeout
4013
Setting Password Access Timeout
4014
Invalid Password Attempts (before lockout)
4015
Password Lockout Duration
4016
Password Access Events
4017
Local Setting Authorization
4018
Remote Setting Authorization
4019
Access Authorization Timeout
User Display Invoke (Read/Write Setting)
4040
Invoke and Scroll Through User Display Menu Operand
LED Test (Read/Write Setting)
4048
LED Test Function
4049
LED Test Control
Preferences (Read/Write Setting)
404F
Language
4050
Flash Message Time
4051
Default Message Timeout
4052
Default Message Intensity
4053
Screen Saver Feature
B-14
RANGE
0 to 99
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
5 to 480
5 to 480
2 to 5
5 to 60
0 to 1
1 to 65535
0 to 65535
5 to 480
0 to 65535
0 to 1
0 to 65535
0 to 4
0.5 to 10
10 to 900
0 to 3
0 to 1
B90 Low Impedance Bus Differential System
APPENDIX B
UNITS
STEP
FORMAT
min
1
F001
---
1
F126
---
1
F126
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F126
---
1
F126
---
1
F126
---
1
F126
---
1
F003
---
1
F003
---
1
F050
---
1
F126
---
1
F155
---
1
F108
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F102
---
1
F102
minutes
1
F001
minutes
1
F001
---
1
F001
minutes
1
F001
---
1
F102
---
1
F300
---
1
F300
minutes
1
F001
---
1
F300
---
1
F102
---
1
F300
---
1
F531
s
0.1
F001
s
1
F001
---
1
F101
---
1
F102
DEFAULT
3
0 (No)
1 (Yes)
1 (Enabled)
1 (Enabled)
0 (Disabled)
1 (Enabled)
1 (Enabled)
1 (Enabled)
0 (No)
0 (No)
0 (No)
0 (No)
0
0
0
0 (No)
0 (Offline)
0 (Off)
0
0
0
0
0 (Disabled)
0 (Disabled)
5
30
3
5
0 (Disabled)
1
1
30
0
0 (Disabled)
0
0 (English)
10
300
0 (25%)
0 (Disabled)
GE Multilin

Advertisement

Table of Contents
loading

This manual is also suitable for:

B90 ur series

Table of Contents