B.4 MEMORY MAPPING
Bitmask
Error
2
Port 1 Offline
3
Port 2 Offline
4
Port 3 Offline
5
Port 4 Offline
6
Port 5 Offline
7
Port 6 Offline
B
8
RRTD Communications Failure
9
Voltage Monitor
10
FlexLogic Error Token
11
Equipment Mismatch
12
Process Bus Failure
13
Unit Not Programmed
14
System Exception
15
Latching Output Discrepancy
16
Ethernet Switch Fail
17
Maintenance Alert 01
18
SNTP Failure
19
---
20
Primary Ethernet Fail
21
Secondary Ethernet Fail
22
Temperature Monitor
25
Field RTD Trouble
26
Field TDR Trouble
27
Remote Device Offline
28
Direct Device Offline
29
Direct Input/Output Ring Break
30
Any Minor Error
31
Any Major Error
32
IEC 61850 Data Set
33
Aggregator Error
34
---
35
---
36
Watchdog Error
37
Low On Memory
38
---
43
Module Failure 01
44
Module Failure 02
45
Module Failure 03
46
Module Failure 04
47
Module Failure 05
48
Module Failure 06
49
Module Failure 07
50
Module Failure 08
51
Module Failure 09
52
Incompatible Hardware
53
Module Failure 10
54
Module Failure 11
55
Module Failure 12
F143
UR_UINT32: 32 BIT ERROR CODE (F141 specifies bit number)
A bit value of 0 = no error, 1 = error
B-58
F144
ENUMERATION: FORCED CONTACT INPUT STATE
0 = Disabled, 1 = Open, 2 = Closed
F146
ENUMERATION: MISCELLANEOUS EVENT CAUSES
Bitmask
F152
ENUMERATION: SETTING GROUP
0 = Active Group, 1 = Group 1, 2 = Group 2, 3 = Group 3
4 = Group 4, 5 = Group 5, 6 = Group 6
F155
ENUMERATION: REMOTE DEVICE STATE
0 = Offline, 1 = Online
B90 Low Impedance Bus Differential System
Definition
0
Events Cleared
1
Oscillography Triggered
2
Date/time Changed
3
Default Settings Loaded
4
Test Mode Forcing On
5
Test Mode Forcing Off
6
Power On
7
Power Off
8
Relay In Service
9
Relay Out Of Service
10
Watchdog Reset
11
Oscillography Clear
12
Reboot Command
13
LED Test Initiated
14
Flash Programming
15
Fault Report Trigger
16
User Programmable Fault Report Trigger
17
---
18
Reload CT/VT module Settings
19
---
20
Ethernet Port 1 Offline
21
Ethernet Port 2 Offline
22
Ethernet Port 3 Offline
23
Ethernet Port 4 Offline
24
Ethernet Port 5 Offline
25
Ethernet Port 6 Offline
26
Test Mode Isolated
27
Test Mode Forcible
28
Test Mode Disabled
29
Temperature Warning On
30
Temperature Warning Off
31
Unauthorized Access
32
System Integrity Recovery
33
System Integrity Recovery 06
34
System Integrity Recovery 07