Measured variable

Measuring range

Media group
DC (ε
)
r
1
1.4...1.6
2
1.6...1.9
3
1.9...2.5
4
2.5...4
5
4...7
6
> 7
1)
The measuring range for interface measurement is limited to 10 m (33 ft).
12

Input

The measured variable is the distance between the reference point and the product surface.
Subject to the empty distance entered "E" the level is calculated.
Alternatively, the level can be converted into other variables (volume, mass) by means of
linearization (32 points).
The following table describes the media groups and the possible measuring range as a function of
the media group.
Levelflex FMP51, FMP54
Typical liquids
condensed gases, e.g. N
, CO
2
2
• liquefied gas, e.g. propane
• solvent
• Freon
• palm oil
mineral oils, fuels
• benzene, styrene, toluene
• furan
• naphthalene
• chlorobenzene, chloroform
• cellulose spray
• isocyanate, aniline
• aqueous solutions
• alcohols
• ammonia
bare metallic
rod probes
on request
one-piece: 4 m (13 ft)
15 to 22 m (49 to 72 ft)
divisible: 10 m (33 ft)
one-piece: 4 m (13 ft)
22 to 32 m (72 to 105 ft)
divisible: 10 m (33 ft)
one-piece: 4 m (13 ft)
divisible: 10 m (33 ft)
one-piece: 4 m (13 ft)
divisible: 10 m (33 ft)
one-piece: 4 m (13 ft)
divisible: 10 m (33 ft)
Levelflex FMP51, FMP52, FMP54
1)
Measuring range
bare metallic
rope probes
32 to 42 m
(105 to 138 ft)
42 to 45 m
(138 to 148 ft)
45 m (148 ft)
coax probes
6 m (20 ft)
6 m (20 ft)
6 m (20 ft)
6 m (20 ft)
6 m (20 ft)
6 m (20 ft)
Endress+Hauser