Application Macro Premagnetise - ABB ACS 140 Programming Manual

Hide thumbs Also See for ACS 140:
Table of Contents

Advertisement

Application Macro Premagnetise

This macro is intended for those applications where the drive must start very
quickly. Building up the flux in the motor always takes time. With the
Premagnetise Macro, this delay can be eliminated.
The value of parameter 9902 is 7.
Input signals
• Start, stop and direction (DI1,2) • An. output AO: Frequency
• Analogue reference (AI1)
• Preset speed selection (DI3,4)
• Premagnetise (DI5)
mA
*Constant speed selection: 0 = open, 1 = connected
DI3
DI4
0
0
1
0
0
1
1
1
Premagnetise parameter values:
9905
MOTOR NOM VOLT
9907
MOTOR NOM FREQ
9908
MOTOR NOM SPEED
1001
1
EXT
COMMANDS
1002
2
EXT
COMMANDS
1003
DIRECTION
1101
KEYPAD REF SEL
1102
1/
2
EXT
EXT
SEL
1103
1
EXT REF
SELECT
22
Output signals
Control
Terminals
1
SCR
2
AI 1
3
AGND
4
10 V
5
AI 2
6
AGND
7
AO
8
AGND
9
+12 V
10 DCOM
11 DI 1
12 DI 2
13 DI 3
14 DI 4
15 DI 5
16 DO 1A
17 DO 1B
18 DO 2A
19 DO 2B
Output
Reference through AI1
Constant speed 1 (1202)
Constant speed 2 (1203)
Constant speed 3 (1204)
230/400 V
50 Hz
1440 rpm
2 (
1,2)
DI
0 (
NOT SEL
3 (
REQUEST
1 (
REF
6 (
EXT
1 (
KEYPAD
• Relay output 1: Fault
• Relay output 2: Running
Function
External reference1: 0...10 V <=> 0...50 Hz
Reference voltage 10 VDC
Not used
Output frequency 0...20 mA <=> 0...50 Hz
+12 VDC
Start/Stop: Activate to start ACS 140
Fwd/Rev: Activate to reverse rotation direction
Constant speed select*
Constant speed select*
Premagnetise: Activate to start premagnetising
1105
EXT REF
1106
EXT REF
1201
CONST SPEED SEL
1503
AO CONTENT MAX
)
1601
RUN ENABLE
)
2008
MAXIMUM FREQ
1)
2105
PREMAGN SEL
1)
2201
ACC
)
U/I Jumper S1
S1:1:U
Relay output 1
Relay output 2
Running: closed
1
50 Hz
MAX
2
0 (
SELECT
7 (
50 Hz
0 (
50 Hz
5 (DI5)
/
1/2
0 (
DEC
SEL
Fault: open
)
KEYPAD
3,4)
DI
)
NOT SEL
)
NOT SEL