Menu Functions; Resetting The Drive From The Control Panel - ABB ACS 140 Programming Manual

Hide thumbs Also See for ACS 140:
Table of Contents

Advertisement

Menu Functions

Scroll the Parameter groups for the desired menu function. Press and hold
ENTER until the display blinks to start the function.
1 Copy parameters from panel to drive (download)
Note! Drive must be stopped and in local control. Parameter 1602
PARAMETER LOCK
2 Copy parameters from drive to panel (upload)
Note! Drive must be stopped and in local control. Parameter 1602
PARAMETER LOCK
3 Select between basic and full menu
Visible if Full
menu is active

Resetting the Drive from the Control Panel

When the red LED of the ACS 140 is on or blinking, a fault is active.
To reset a fault when the red LED is on, press the START/STOP button.
Caution! This may start the drive, when in remote control.
To reset a fault when the red LED is blinking, turn the power off.
Caution! Turning the power on again may start the drive immediately.
The relevant fault code (see Diagnostics) flashes in the panel display until the
fault is reset or the display is "cleared".
You can "clear" the display without resetting the fault by pressing any button.
The word FAULT will be displayed.
Note! If no other button is pressed within 15 seconds and the fault is still
active, the fault code will be displayed again.
After a power failure, the drive will revert to the same control mode (LOC or
REM) as before the power failure.
MENU
must be set to 1 (
MENU
must be set to 1 (
MENU
Press & hold
(17(5
).
OPEN
Press & hold
(17(5
).
OPEN
Press & hold
(17(5
5