Code Name
Group 21
START/STOP
2102
STOP FUNCTION
Conditions during motor stopping.
1 =
COAST
Motor coasts to stop.
2 =
RAMP
Ramp deceleration as defined by the active deceleration time 2203
DECELER TIME
Default value: 1 (
Group 22
ACCELER/DECELER
2202
ACCELER TIME
Ramp 1: time from zero to maximum frequency (0 -
Range for all ramp time parameters is 0.1 - 1800 s.
Default value: 5.0 s
2203
DECELER TIME
Ramp 1: time from maximum to zero frequency (
Default value: 5.0 s
2204
ACCELER TIME
Ramp 2: time from zero to maximum frequency (0 -
Default value: 60.0 s
2205
DECELER TIME
Ramp 2: time from maximum to zero frequency (
Default value: 60.0 s
Group 26
MOTOR CONTROL
2606 U/f
RATIO
U/f below field weakening point.
1 =
LINEAR
2 =
SQUARE
L
is preferred for constant torque applications.
INEAR
preferred for centrifugal pump and fan applications to increase motor
efficiency and to reduce motor noise.
Default value: 1 (
Group 33
INFORMATION
3301
SW VERSION
Software version code.