2. Connect the power pack to power source.
Caution:
Do not connect to a receptacle controlled by a switch!
CAUTION: Wall tamper is an optional security feature that is disabled by default. When
enabled, the siren will make a very loud alarm sound when power is connected. Press
9 7 1 3 Enter to turn the siren off. If this does not work, try 1234 as User 1.
Lights should be lit on the ZeroWire when the power is turned on. If not check that the
power lead is connected securely to the rear of the ZeroWire.
Avoid using multiple power adapters and power boards.
Note:
ZeroWire should be connected to a power source at all times. The battery is a
backup power source, and the ZeroWire is designed to run on the battery pack during a
power failure only, and NOT for prolonged periods of time.

Reset Installer Account

1. Disconnect power
2. Use a small screwdriver to hold down the reset button
3. Turn on power and keep holding down reset button for 3 seconds, then release the
reset button. This will reset PIN to 9713 and username "installer", this account will not
have access to user programming.
4. Default panel to restore all settings to factory defaults. See page 25.
Checking Signal Level
On the ZeroWire key pad:
ZeroWire Installation Manual